《消防给水及消火栓系统技术规范》常见问题探讨
Common Problems in Technical Code for Protection Water Supply and Hydrant Systems
汪小明 1康凯1
作者信息
- 1. 中机第一设计研究院有限公司,合肥 230601
- 折叠
摘要
结合工作实践及在实际工作中遇到的问题,参照对规范的理解,对消防系统中压力开关、流量开关、吸水口、水泵接合器、消火栓按钮及高位消防水箱等消防设施的设置问题,以及消防系统工作压力、两路消防供水等管路系统等常见问题进行了分析和总结,并提出相应的解决方案.
Abstract
The author combined the work practice and problems encountered in the actual work,referring to the understanding of the code,analyzes and discusses the setting problems of fire protection facilities such as pressure switch,flow switch,suction port,water pump adapter,fire hydrant button and high fire water tank in the fire protection system;The common problems of the pipeline system such as the working pressure of the fire protection system and the two-way fire water supply,and puts forward corresponding solutions.
关键词
压力开关/吸水口/高位消防水箱/系统工作压力/两路消防供水Key words
pressure switch/water intake/high-level fire water tank/system working pressure/two-way fire water supply引用本文复制引用
出版年