Analysis of Delay Distribution Characteristics and Disturbance Control of Clean Heating Network Based on Heat Current Method
Under the background of double carbon strategy,with the frequent occurrence of extreme weather and the increasing heat load of customers,it is an important development direction of the heating network to further increase the stability of the heating system and reduce the heating energy consumption.This paper addresses the typical disturbance control problems of heating networks,constructs a dynamic heat flow model of the whole link of the heating network based on the physical model of the heating network,analyzes the problems of delay distribution characteristics of each major equipment in the heating network and the heating network as a whole,and explores the actual heating strategy of the heating network as well as the influence and control of heating disturbances.The results show that the delay of the heating network is mainly concentrated in the radiator side,and the delay time of the radiator accounts for about 86.6%of the delay time of the whole heating network;this paper explores the actual heating strategy by taking the outdoor temperature of a day in Beijing as an example,and simulates that the energy saving of the new heating strategy adopted in the face of the heating disturbance is 2.61%and 2.91%,respectively.