广东化工2024,Vol.51Issue(13) :118-120,126.DOI:10.3969/j.issn.1007-1865.2024.013.031

同位素稀释-高分辨气相色谱/高分辨质谱法测定鱼油中总多氯联苯

Determination of Total Congeners in Fish Oil:Isotope Dilution HRGC/HRMS

江海飞
广东化工2024,Vol.51Issue(13) :118-120,126.DOI:10.3969/j.issn.1007-1865.2024.013.031

同位素稀释-高分辨气相色谱/高分辨质谱法测定鱼油中总多氯联苯

Determination of Total Congeners in Fish Oil:Isotope Dilution HRGC/HRMS

江海飞1
扫码查看

作者信息

  • 1. 通标标准技术服务(上海)有限公司,上海 200233
  • 折叠

摘要

多氯联苯是主要的持久性有机污染物分类之一,总多氯联苯是 IFOS 五星认证中一项重要限制性指标.本文建立了一种同位素稀释-高分辨气相色谱/高分辨质谱测定鱼油中209 种多氯联苯总含量的分析方法.鱼油样品经正己烷萃取后,经过浓缩、净化,经过同位素标识过程,使用高分辨气相色谱/高分辨质谱(HRGC-HRMS)对目标物进行测定.鱼油中总多氯联苯的检出限为1.4 ng/g,定量下限为5.4 ng/g.

Abstract

PCBs is one major category of Persistent Organic Pollutants(POPs),and total 209 Congeners is restrictive indicator for IFOS five-star authentication.A method had been developed for determination of total 209 Congeners in fish oil by isotope dilution HRGC/HRMS.After fish oil samples were extracted with hexane,the extraction solution is concentrated,purified,and subjected to isotope labeling.The target substance is determined using HRGC-HRMS.The method detection limit is 1.4 ng/g,and minimum quantitative detection limit is 5.4 ng/g.

关键词

鱼油/二噁英/总多氯联苯/高分辨气相色谱/高分辨质谱/同位素内标/持久性有机污染物

Key words

fish oil/dioxin/total Congeners/high-resolution gas chromatography-high-resolution mass spectrometry/isotope internal standard/persisent organic pollutants