CFG桩复合地基是工程中常用的软弱地基处理方法,而使用较短桩长的CFG桩甚少.本文以广州市黄埔区某环山软弱地基作为试验区域,主要对桩长不同的CFG桩复合地基进行平板载荷试验.结果表明,CFG桩的桩长在5m范围内,其利用率最大的长度为3.0m~3.5m;同时,CFG桩复合地基中承受荷载时,CFG桩桩长小于中性面Z0深度且桩侧土弹性模量远小于CFG桩弹性模量时,其处理效果不佳.
Treatment Effect and Discussion of CFG Short Piles in Treating Soft Foundation
CFG pile composite foundation is a common soft foundation treatment method in engineering,but the shorter CFG pile is rarely used.In this paper,a soft foundation around a mountain in Huangpu District of Guangzhou is taken as the test area,and the plate load test is mainly carried out on CFG pile composite foundation with dif-ferent pile lengths.The results show that the maximum utilization length is 3.0m~3.5m for the length of CFG pile within 5m.At the same time,the treatment effect is worse when the CFG pile length is less than the Z0 and the elastic modulus of the soil on the side of the pile is much less than the CFG pile with the load borne in the com-posite foundation.

CFG pileComposite foundationFoundation treatmentBearing capacity of foundation

吴宇豪、许宇星、王晓伟、关应良、赵仕源

展开 >

广州建设工程质量安全检测中心有限公司

广州市建筑科学研究院集团有限公司

CFG桩 复合地基 地基处理 地基承载力