The Bioelement Content Determination and Functional Evaluation of Quinton Drinkable Sea Water From Spain
Objective To develop bioelement content determination and functional evaluation protocol of Quinton drinkable sea water from Spain by ICP-MS.(In this artical bioelement refers specifically to the macro elements and trace elements needed by human body).Methods A method of simultaneous determination of 21 kinds of bioelements in Quinton drinkable sea water was established by inductively coupled plasma mass spectrometry(ICP-MS).Results The detection limit is 0.01~0.10 μg/mL,the recovery is 94.12%~104.35%,the relative standard deviation is 0.3%~12.2%.Conclusion The method is simple,rapid and accurate.It is suitable for simultaneous determination of multi-element content in sea water.And evaluate the properties and functions of Quinton drinkable sea water based on element content.