变压器作为电力系统中的重要核心设备之一,其油箱内部易产生电弧故障,从而产生超压,致使油箱破裂,导致漏油,严重时引起爆炸甚至火灾,对电力系统的稳定运行造成严重威胁.该文针对变压器内部电弧故障从压力波特性、仿真模型、油中电弧检测方法以及防爆技术等方面进行回顾,首先对压力波特性、仿真模型以及压力波传播规律进行了综述,其中重点介绍了 4 种压力波仿真模型并对比其优缺点;其次,根据电弧故障检测难度大、破坏性强等特点归纳了油中电弧检测技术及标准;此外,分析探讨了变压器电弧故障的关键防爆技术.最后根据电弧故障以及防爆技术分析现有挑战,并在此基础上对未来发展趋势进行展望.
Review of Arc Discharge Fault Detection and Explosion-proof Technology in Transformer Oil
As one of the important core devices in the power system,the transformer is prone to arc failure in its fuel tank,which may generate overpressures,resulting in a fuel tank rupture,resulting in oil leakage,explosion,or even fire in seri-ous cases,thus poses a serious threat to the stable operation of the power system.In this paper,the internal arc fault of the transformer is reviewed from the aspects of pressure wave property,simulation model,oil arc detection method explo-sion-proof technology,etc.Firstly,the pressure wave property,simulation model,and pressure wave propagation law are reviewed including four pressure wave simulation models,and their advantages and disadvantages are compared.Sec-ondly,in accordance with the characteristics of difficulty and destructive operation in the arc fault detection,the technology and the standard of arc detection in oil are summarized.In addition,key explosion-proof technology for transformer arc faults is analyzed and discussed.Finally,current challenges are analyzed according to arc fault and explo-sion-proof technology future development trend is forecast on this basis.

transformerarc faultpressure wavearc detectionexplosion-proof technology

刘凯、樊立科、聂广博、焦世伯、邓军、吴广宁

展开 >

西南交通大学电气工程学院,成都 611756

中国南方电网有限责任公司超高压输电公司,广州 510663

变压器 电弧故障 压力波 电弧检测 防爆技术

国家自然科学基金国家自然科学基金四川省自然科学基金国家重点研发计划

52377161520071582023NSFSC08312022YFB4301202-17

2024

高电压技术
中国电力科学研究院 中国电机工程学会

高电压技术

CSTPCD北大核心
影响因子:2.32
ISSN:1003-6520
年,卷(期):2024.50(10)