首页|Comparative chemical sensor for detection of chromium(Ⅵ)in aqueous solution

Comparative chemical sensor for detection of chromium(Ⅵ)in aqueous solution

扫码查看
A process for purifying aqueous solutions containing heavy and toxic metals such as chromium(Cr)has been investi-gated.One of the extremely harmful pollutants in rivers and seawater is the heavy metal ions due to their direct im-pacts on human,animals and plants are hexavalent Cr(Ⅵ).Consequently,highly sensitive sensor to detect Cr is es-sential.Surface plasmon resonance(SPR)technique has attracted huge research interest in detecting heavy metals spe-cifically.In this study,three types of prism-based SPR sensor,gold(Au)/silver(Ag),Au/polyaniline(PANI)and Au/titanium dioxide(TiO2)nanostructured films,are investigated as potential sensing material to detect the presence of Cr(VI)ions in water.The base Au layer with thickness of 48.3 nm is deposited on a glass slide for all sensors.For Au/Ag,Au/PANI nanofibers and Au/TiO2 sensor films,the Cr(Ⅵ)concentration is varied from 1 ppm to 15 ppm with sensitivity of 0.270 °ppm-1,0.082 °ppm-1 and 0.039 °ppm-1,respectively.Based on these results,the Au/PANI nanofi-bers are the most sensitive to Cr(Ⅵ)among the tested sensing materials.

Sura H.AL-REKABI、A.A.ALWAHIB

展开 >

Electrical Technique Department,Al Suwayrah Technical Institute,Middle Technical University,Baghdad,Iraq

Laser and Optoelectronics Department,University of Technology-Iraq,Baghdad Iraq

2025

光电子快报(英文版)
天津理工大学

光电子快报(英文版)

影响因子:0.641
ISSN:1673-1905
年,卷(期):2025.21(1)