风帽作为循环流化床锅炉燃烧设备的核心部件,直接决定着循环流化床锅炉的流化质量,从而影响锅炉的安全性和经济性.针对450 t/h循环流化床锅炉出现的炉膛风帽漏渣问题,结合空床阻力特性试验和数值模拟结果,发现风帽漏渣的原因在于风帽阻力明显偏低,运行工况下风帽阻力仅为2 kPa.结合锅炉运行情况和改造周期,采用了更换风帽帽头来提升风帽阻力的优化改造方案,改造后风帽阻力提升到4.1 kPa,成功地解决了风帽漏渣问题,提高了锅炉的安全性和经济性.
Modification for the Nozzle in the Furnace of 450 t/h Circulating Fluidized Bed Boiler
As a core component of the combustion equipment of circulating fluidized bed boiler,the nozzle directly determines the fluidization quality of the boiler,thereby affecting its safety and economy.Addressing the issue of ash leakage from the furnace nozzle in a 450 t/h circulating fluidized bed boiler,combined with tests on the resistance characteristics of an empty bed and numerical simulation results,it was found that the cause of the ash leakage was the significantly low pressure drop of the nozzle,which was only 2 kPa under operating conditions.Taking into account the boiler's operating conditions and the modification time,an optimized modification plan was adopted to replace the cap of the nozzle in order to increase its pressure drop.After the modification,the pressure drop of the nozzle increased to 4.1 kPa,successfully resolving the problem of ash leakage from the nozzle and improving the safety and economy of the boiler.