采用防城河长歧水文站2011-2020年水位、流量实测资料,利用校正因数法对其水位流量关系进行单值化分析,结果符合规范关于流量间测的规定和要求,该站水位在29.40-35.00m水位级内可实行间测,间测期间采用历年水位流量关系综合曲线推求流量,其他水位按原测验方案进行测验并推流.
Application of correction factor method in water level and flow uniformization analysis for Changqi Hydrological Station
For Changqi Hydrological Station on Fangchenghe River,based on the water level and flow measuring da-ta from 2011 to 2020,uniformization analysis of level-flow relationship was conducted by correction factor method,with the results in conformity with the specifications for flow intermittent measurement.The water level of this sta-tion can be measured intermittently within the water level range of 29.40-35.00m.During the intermittent measure-ment period,the flow can be calculated by use of the comprehensive curve of the water level and flow relationship over the years.Other water levels will be measured and calculated according to the original measurement plan.

correction factor methoduniformizationChangqi Hydrological StationFangchenghe River

严焕宇

展开 >

广西沿海水文中心防城港水文测报中心,广西防城港 538021

校正因数法 单值化 长歧水文站 防城河

2024

广西水利水电
广西水利电力勘测设计研究院

广西水利水电

影响因子:0.135
ISSN:1003-1510
年,卷(期):2024.(1)