Comparative measurement analysis of fixed radar flow measuring system for Wenxu Hydrological Station
Real-time acquisition of water level and flow data is realized at Wenxu Hydrological Station by use of ra-dar flow measuring system,which solve the medium and high flow measuring problem and reduce the work load.The index flow velocity measured with radar flow measuring system is compared with the sectional flow velocity mea-sured with navigable ADCP,based on which the relationship between sectional velocity and index velocity is con-firmed,and the fixed line flow is calculated by index flow velocity conversion.The results of analysis demonstrate the radar measuring system is suitable for the measuring conditions of Wenxu Hydrological Station,with the mea-surement accuracy meeting the requirements of specification.
radar flow measuring systemcomparative measurement analysisWenxu Hydrological Station