首页|磁场对脉冲展宽分幅相机空间电荷效应的影响

磁场对脉冲展宽分幅相机空间电荷效应的影响

扫码查看
基于磁聚焦成像的脉冲展宽分幅相机是具有超快时间分辨的诊断设备,空间电荷效应是制约其时空性能向更高量级提升的主要因素。为研究脉冲展宽分幅相机中的空间电荷效应,基于电子脉冲电势分布和电场力方程建立研究模型,将电子脉冲动态特性融入模型分析。研究结果显示,由成像磁场引起的电子脉冲动态半径对空间电荷效应时空弥散影响显著,当轴上磁场强度为4。585×10-3T时,随着离轴位置增加至15 mm,磁场强度提高到4。763×10-3T;由于离轴电子脉冲散焦使动态半径较大,因此在降低电子密度的同时,使空间电荷效应的时间弥散由2。94 ps减小至483 fs,空间弥散由668 μm减小至22 μm;当轴上磁场强度由4。585×10-3T降低至3。359×10-3T时,与最优空间分辨性能相似,空间电荷效应时空弥散在磁场3。4×10-3~3。5×10-3T区域内达到最小,此时离轴15 mm内的时间弥散范围为256~392 fs,空间弥散范围为3。1~15。4 μm。研究结论为分析磁场对脉冲展宽分幅相机空间电荷效应的影响提供一定的理论参考。
Influence of Magnetic Field on Space Charge Effect in Pulse-Dilation Framing Camera
Objective In the inertial confinement fusion(ICF)experiment,the microchannel plate(MCP)framing camera is an important two-dimensional ultrafast diagnostic device that is used to acquire the duration and dynamic image of plasma at the stage of implosion compression.However,due to limitations of the electronic transmission time and its dispersion in the channel of the MCP,the temporal resolution is restricted to 60-100 ps for a long time.In order to further improve temporal resolution,a pulse-dilation framing camera(PDFC)is developed,which couples the MCP framing camera with the temporal dilation technique of the electron beam.With an ultrafast temporal resolution of better than 10 ps,it is easier to meet the detection requirements of the shorter duration states in the ICF.Therefore,the relevant ways and techniques of the PDFC are gradually focused on the field of ultrafast diagnosis.The PDFC is a new kind of framing camera with a long drift region using the imaging of magnetic focusing technique.Due to its similar structure to the streak camera,the improvement of its spatio-temporal performance to a higher order is restricted by the space charge effect(SCE).Moreover,the temporal width and radius of the electronic pulses(EPs)are dynamically changed by the dilating pulse and magnetic focusing in the PDFC.Therefore,building the model of the SCE that meets the dynamic parameters of the EPs and analyzing the influence of the dynamic radius caused by magnetic focusing on the spatio-temporal dispersions will be an important theoretical significance for systemically studying the SCE of the PDFC.Methods In the research,to analyze the influence of magnetic field on the spatio-temporal dispersions of the SCE,first of all,the model of the PDFC using magnetic focusing is built,and the dynamic characteristics of EPs during transmission are analyzed by the working principle of the PDFC.Then,the spatio-temporal dispersion model of the SCE is deduced by solving the equation of the electric field force based on the two-dimensional potential distribution of the EPs.To build a relationship between magnetic field and imaging area,while ensuring consistent imaging magnification,the different imaging magnetic fields are reasonably calibrated through the analysis procedure of optimal spatial performance of the PDFC based on the method of regional imaging.Finally,the dynamic temporal width and radius of the EPs are applied to the model of the SCE in different magnetic fields,and the spatio-temporal dispersions of different off-axis positions are analyzed.Results and Discussions The innovative and significant research results are mainly summarized in three aspects.First,the dynamic variation of the electronic density during transmission is analyzed in the PDFC,on which the dynamic temporal width and radius of the EPs are based[Fig.2(d)].Second,under consistent imaging magnification,the optimal spatial performance of the PDFC is analyzed,and different imaging magnetic fields are reasonably calibrated by regional imaging(Fig.3).Third,the dynamic temporal width and radius of the EPs are applied to the model of the SCE.When the radius of the imaging region is 1 mm,as the off-axis position increases from 0 mm to 15 mm,the magnetic field intensity is enlarged from 4.585 ×10-3 T to 4.763 ×10-3 T.The defocusing and dynamic radius of EPs of the off-axis are much larger than those of the on-axis.Therefore,as the electronic density of the EPs reduces,the temporal dispersion of the SCE is reduced from 2.94 ps to 483 fs,and the spatial dispersion is reduced from 668 μm to 22 μm(Fig.4).When the radius of imaging region is gradually enlarged to 20 mm,the magnetic field intensity of the on-axis is reduced from 4.585× 103 T to 3.359× 10-3 T,and the spatio-temporal dispersions of the SCE are optimum value in the range of 3.4× 10-3-3.5× 10-3 T.The range of temporal dispersions of different positions is 256-392 fs,and spatial dispersions is 3.1-15.4 μm(Fig.5).Conclusions In the PDFC,the temporal width,radius,and electronic density of the EPs during the transmission process are dynamically changed by the effect of the dilating pulse and the imaging system of magnetic focusing.Moreover,the spatio-temporal dispersions of the SCE are significantly affected by the defocusing of the EPs and the fluctuation of radius caused by a magnetic field.According to the research methods and results,on the one hand,the different magnetic field is reasonably calibrated through the analysis of the optimal spatial performance of the PDFC;on the other hand,it also provides a theoretical basis for analyzing the relationship between the magnetic field and the SCE.In the next stage,to provide a theoretical basis for achieving faster temporal resolution of the PDFC,the spatio-temporal dispersions of the SCE are systematically studied from different types of magnetic focusing imaging systems and the long drift regions.

ultrafast opticsultrafast diagnosis techniquepulse-dilation framing cameraspace charge effectimaging magnetic fieldspatio-temporal dispersion

白雁力、宋明诚、朱望纯

展开 >

桂林电子科技大学电子工程与自动化学院,广西桂林 541004

超快光学 超快诊断技术 脉冲展宽分幅相机 空间电荷效应 成像磁场 时空弥散

国家自然科学基金广西自然科学基金广西自动检测技术与仪器重点实验室主任基金广西图像图形与智能处理重点实验室(桂林电子科技大学)开放基金

118650072022GXNSFAA035561YQ22101GIIP2210

2024

光学学报
中国光学学会 中国科学院上海光学精密机械研究所

光学学报

CSTPCD北大核心
影响因子:1.931
ISSN:0253-2239
年,卷(期):2024.44(5)
  • 3