首页|双斜锥光纤布拉格光栅超声波传感装置

双斜锥光纤布拉格光栅超声波传感装置

扫码查看
为提高光纤布拉格光栅(FBG)在超声波探测中的灵敏度和复用能力,设计并实现一种基于聚能耦合效应的双斜锥FBG超声波传感装置。首先,利用锥聚能理论与有限元法,分析锥形结构对超声波的聚焦作用。其次,详细讨论双斜锥FBG的结构参数(斜锥锥角、底面直径、高度、倾斜度)对其聚能效果的影响,确定传感装置最优尺寸。最后,制作传感装置并测试其动态特性。结果表明,封装后的双斜锥FBG超声波传感装置在20~130 kHz工作频率范围内可有效提高FBG检测超声波灵敏度。当工作频率增加到50 kHz时,检测幅值提升了约21倍,且传感响应的线性度良好。设计的超声波传感装置可实现双端输出,具有复用性,可应用于钢轨、桥梁等长距离结构的健康监测。
Design of Fiber Bragg Grating Ultrasonic Sensor with Dual-Slant Cone Structure
Objective Railway transport is an important part of China's transportation strategy and is still in the high-speed construction stage,with its total operation mileage reaching 1.59×105 km.As the direct carrier of train operation,the inside and surface of rails will have a variety of defects and damages due to long-term operation and vibration shock.What's worse,this will directly endanger the safety of trains and passengers if defects or damages are not found and repaired in time.At present,piezoelectric sensors are usually employed to detect ultrasonic rail damage and each of them needs a power line connection,which makes it difficult to achieve multi-point multiplexing detection.In contrast,optical fiber Bragg grating(FBG)has the unique advantages of electromagnetic interference resistance,easy reuse,and corrosion resistance,which makes it suitable for damage detection of long-distance structures such as steel rails in harsh environments.To detect ultrasonic waves,we propose and design a high-sensitivity FBG ultrasonic sensor based on a coupled dual-slant cone structure.Meanwhile,the optimal size of the sensor is analyzed and determined,with the sensor object made.The dynamic characteristics of the sensor are tested experimentally,with a new approach provided for long-distance structure ultrasonic detection.Methods First,the optimal sensor size is obtained.Based on the mechanism of FBG and ultrasonic waves and the principle of slant conical energy accumulation,the slant conical sensor is modeled and solved by COMSOL simulation software 6.0.The amplitudes of ultrasonic signals detected by non-conical,positive conical,and slant conical structures are analyzed and compared respectively.The influence of slant conical structure parameters β,d,H,and i on the sensor performance is studied in detail.Then,three-dimensional(3D)printing technology is adopted to make the entity of the sensor device.After that,a narrow-band light source demodulation system is built to detect ultrasonic signals of different frequencies.Finally,the performance of PZT,bare FBG,and mono-clinic cone sensing devices is tested and compared.Results and Discussions Sensor structure size is analyzed and optimized.The verification effect of angle β on the performance of the slant cone shows that when β=25°‒35°,the pressure and x-axis displacement at FBG have larger values.The effect of the bottom diameter d on the performance of the slant cone shows that when β=30° and d=10 mm,the maximum pressure and displacement are 707 Pa and 1.7×10-7 mm respectively.The effect of base height H on the performance of the slant cone shows that when β=30°,d=10 mm,and H=12.5mm,the pressure and displacement have maximum values of 880 Pa and 2.4×10-7 mm respectively.Meanwhile,it is found that the slope i of the slant cone is also an important factor affecting the structure energy concentration.When i=1.138,the pressure at the tip of the cone is the maximum.By comparing the maximum and minimum values of different parameters,we find that each parameter has a great influence on the sensor performance.The maximum pressure is 880 Pa,and the minimum pressure is 47 Pa,with a difference of about 18.6 times.The maximum displacement is 2.4×10-7 mm,the minimum is 1.1×10-8 mm,and the difference is about 21.8 times.It is determined that the ideal size of the sensor is β=30°,d=10 mm,H=12.5 mm,and i=1.138.In this case,the cone has a strong ultrasonic focusing ability and a greater effect on ultrasonic detection improvement by FBG.A narrow-band light source system is built to detect sinusoidal ultrasonic signals.The experimental results show that the dual-slant cone FBG sensor has strong resolution and the ability to detect ultrasonic waves in the range of 20‒150 kHz,and the response voltage has a good linear relationship with the drive voltage.In the detection frequency range of 40‒60 kHz,the detection amplitude is 90‒230 mV,the signal-to-noise ratio is 10‒19 dB.The signal-to-noise ratio characteristics of bare FBG,single-slant cone ultrasonic sensing device,piezoelectric sensor,and dual-slant cone ultrasonic sensing device are compared.The test results show that the dual-slant cone and single-slant cone FBG ultrasonic sensors have a higher signal-to-noise ratio of ultrasonic signals than piezoelectric sensors in the frequency range of 40‒70 kHz.The noise of piezoelectric sensors is relatively small at about 1‒2 mV,which can achieve a high signal-to-noise ratio.In detecting sinusoidal ultrasonic signals above 80 kHz,the signal-to-noise ratio reaches a maximum of 30 dB,and the signal-to-noise ratio is higher than that of the ultra FBG sensing device.Compared with piezoelectric sensors,the slant cone FBG ultrasonic sensing device has significant advantages in detecting frequencies of 40‒70 kHz.Conclusions To enhance the sensitivity and reuse of FBG ultrasonic sensors,we propose an FBG ultrasonic sensor based on a focusing coupling slant cone structure.Based on the analysis,a physical sensor prototype is fabricated and the dynamic properties of the sensor are experimentally tested.The research results reveal that the encapsulated dual-cone FBG ultrasonic sensor significantly improves the sensitivity of FBG in detecting ultrasonic waves within the frequency range of 20‒130 kHz,and the detection amplitude is increased by about 21 times at 50 kHz.Additionally,the dual-cone sensor has remarkable characteristics of double-end output and strong reuse,which is suitable for applications in long-distance structural damage monitoring such as rails and bridges.

fiber opticsfiber Bragg gratingdual-slant coneultrasonic sensorslant cone focusing

李剑芝、史宇承、吉喆、徐飞、杜彦良

展开 >

石家庄铁道大学河北省大型结构健康诊断与控制重点实验室,河北 石家庄 050043

石家庄铁道大学材料科学与工程学院,河北 石家庄 050043

石家庄铁道大学机械工程学院,河北 石家庄 050043

光纤光学 光纤布拉格光栅 双斜锥 超声波传感器 斜锥聚焦

国家自然科学基金河北省中央引导地方项目河北省省级科技计划资助

51778379226Z0801G21567625H

2024

光学学报
中国光学学会 中国科学院上海光学精密机械研究所

光学学报

CSTPCD北大核心
影响因子:1.931
ISSN:0253-2239
年,卷(期):2024.44(11)