首页|微小体积紫外可见反射式成像光谱仪的光学系统设计

微小体积紫外可见反射式成像光谱仪的光学系统设计

扫码查看
目前,对于成像光谱仪系统的微型化,缺少有效方式来自动获得在固定体积范围内的良好设计起点.提出了一种微型反射式光谱成像仪初始结构的构建方法,建立体积与成像质量之间的联系,基于像差理论合理地缩小潜在结构的数量,求出在体积限制条件下包含色散元件的离轴初始结构,以为新型光谱仪提供准确的设计起始点,之后经过设计软件优化得到理想结果.基于此方法设计了一款在3 L体积限制下的离轴反射式成像光谱仪,设计结果表明:工作谱段为320~500 nm,在奈奎斯特频率(12 lp/mm)处各特征波长的调制传递函数优于0.8,系统弥散斑均方根小于10µm,光谱分辨率达到0.5 nm.整个设计系统的结构紧凑、分辨率高、成像质量好,为相关离轴反射结构设计提供了新思路和新方法.
Optical System Design of UV-Visible Reflective Imaging Micro-Spectrometer
Objective Hyperspectral imaging is an imaging method to acquire spatial and spectral information of a scene.The satellite-based spectrometer can monitor moving targets in real time and is suitable for disaster emergency and target monitoring.In recent years,microsatellite spectrometers have caught increasing attention.Compact optical systems with small size,light weight,and high imaging quality should be designed to improve spatial resolution and reduce production costs.By comparing the characteristics of refractive imaging systems and reflective imaging systems,we find that reflective optical systems are easier to realize compact structures.The reflective imaging system has coaxial and off-axis types.The coaxial layout can fold the optical path,but the central obscuration blocks energy transfer.Meanwhile,the off-axis aberration correction is hard,but it can make full use of energy in off-axis systems.The determination of the initial optical structure is a challenge.A good initial structure greatly determines the efficiency and potential of subsequent optimizations,which will greatly reduce the optimization time and dependence on design experience.Nowadays,based on the generalized flowsheet,the general design of a reflective freeform system is to select a suitable system from a proprietary or existing structure as the starting point and then conduct optimization design in optical software.As special configurations are increasingly being employed,specific design structures are commonly limited for viable starting points.Zhang proposed to design an unobscured initial structure with a reflective freeform imaging system,in which a special algorithm is demonstrated to calculate the data points on the unknown freeform surfaces using the rays from multiple fields and different pupil coordinates,and thus construct multiple freeform surfaces in an imaging system.However,the above method is only suitable for the design of internal systems with less than three mirrors,but the stray light is difficult to suppress for the three-mirror system.Especially,it's complicated for reflective imaging systems with several mirrors.There is still a gap in the initial structure of the reflective spectrometer design method.Methods A novel method of reflective spectrometer structure design is proposed.It is an automatic design method for an off-axis,five-mirror spectrometer based on the Seidel aberration theory.Firstly,if the pitch of mirrors and the mirror curvature of the optical system are known,we can get the heights and paraxial angles on each surface by tracing the characteristic rays in the reflective system.In our study,the height,the angle on each surface,and the mirror curvature are three parameters for reflective optical systems.The optical system of the volumes can be calculated according to three parameters.Meanwhile,based on the aberration theory,we can characterize the primary Seidel aberration terms of the reflective spectrometer system by three parameters.This means that the volume and system aberration are represented by the same three parameters,with the relationship between the volume and the aberration established.Secondly,we consider the characteristics of the spectral system,in which the influence of the grating during light transmission in the system is considered,to ensure that the system meets the imaging conditions of different wavelengths.Then,we derive the mathematical relationships of the relevant parameters of the reflective system.Additionally,the evaluation criteria system is developed to narrow down the structure parameter ranges,thus obtaining the initial compensating optical system aberration under limited volume.Finally,we can import the initial structure into optical design software,which is the off-axis initial system with dispersive elements.As a result,optical systems of UV-visible imaging micro-spectrometers can be quickly optimized.The proposed scheme can satisfy the design requirements,including spectral resolution and spatial resolution.Results and Discussions To verify the feasibility of the method,we design a compact off-axis aspheric reflectance imaging spectrometer by this method.The working spectrum is 320-500 nm,and then the initial off-axis structure can be obtained.Then,freeform surfaces can further improve the imaging quality and expand the field of view.The design results show that the modulation transfer function of each wavelength at Nyquist frequency(12 lp/mm)is greater than 0.8 and the root mean square is better than 10 μm(Fig.11).The Keystone and Smile are smaller than one pixel in the system(Fig.12),with the spectral resolution of 0.5 nm in Fig.13.The system has high resolution and sound imaging quality,thus providing a new idea and method for the design of relevant off-axis reflective structures.Conclusions To meet the development trend of miniaturization of spaceborne spectrometers,we propose a design idea and method suitable for the automation of spectrometers structures under the volume requirement,which shortens the time to find the initial structure and provides a more appropriate initial structure design for reflective structure spectrometers.Given the system design parameters and indicators,an appropriate initial optical system can be generated to accelerate the optimization design in the later stage and greatly reduce the growth compared to traditional optical structure design.Finally,a compact off-axis optical system is obtained with meeting specifications,configurations,and the element number.

optical designimaging spectrometerreflective systemaberration theory

郭宝泽、石恩涛、王咏梅、刘玖、朱军、姚舜

展开 >

中国科学院国家空间科学中心,北京 100190

华北光电技术研究所,北京 100015

天基空间环境探测北京市重点实验室,北京 100190

中国科学院空间环境态势感知技术重点实验室,北京 100190

航天东方红卫星有限公司,北京 100094

展开 >

光学设计 成像光谱仪 反射系统 像差理论

民用航天项目

D010206

2024

光学学报
中国光学学会 中国科学院上海光学精密机械研究所

光学学报

CSTPCD北大核心
影响因子:1.931
ISSN:0253-2239
年,卷(期):2024.44(18)