首页|离心式血液成分分离机校准规范的制定

离心式血液成分分离机校准规范的制定

扫码查看
离心式血液成分分离机在临床上的应用非常广泛,其性能参数准确与否直接影响病人的健康与安全.根据行业标准和设备技术原理,确定其主要计量特性指标和具体的校准方法,并选择代表性的品牌产品进行实验验证.最后依据校准方法对离心式血液成分分离机的计量特性进行验证,验证结果符合确定的计量特性指标要求.该校准规范的制定可以为离心式血液成分分离机量值溯源提供技术依据.
Development of the calibration specification for centrifugal blood component separator
Centrifugal blood component separator is widely used in clinical practice,and the accuracy of its parameters directly affect the health and safety of patients.According to industry standards and equip-ment technical principles,it can determine the main measurement characteristics in metrology and spe-cific calibration methods,and then select products of representative brand for verification.Finally,the measurement characteristics of the centrifugal blood component separator are verified according to the cal-ibration method,and the verification results meet the requirements of the determined measurement char-acteristics.The development of this calibration specification can provide a technical basis for the traceabil-ity of the measurement value of the centrifugal blood component separator.

blood component separationcentrifugalcalibration specificationspeedflow

顾加雨、夏勋荣、庞侃、曹梦伊

展开 >

江苏省计量科学研究院,江苏南京 210023

血液成分分离 离心 校准规范 转速 流量

江苏省市场监督管理局科技计划项目

K.J21125079

2024

工业计量
冶金自动化研究设计院 中国计量协会

工业计量

影响因子:0.256
ISSN:1002-1183
年,卷(期):2024.34(5)