Comparison of Temperature Control Schemes for Three Chamber RTO with Dual Electric Heating
For a three chamber RTO equipped with two sets of electric heating,there are various con-trol schemes for the heating furnace.Different from the furnace with a single group of heat sources,the fur-nace with two groups of heat sources has different temperature control schemes for different sensors.Based on the arrangement of the electric heater and the position of different temperature sensors,the variation curves of furnace temperature under four different control schemes were obtained through experiments.At the same time,by comparing experimental data,the optimal temperature control scheme under different re-quirements can be obtained.
three-room RTOdual electric heatingtemperature control