针对含聚采油废水油含量高且破乳难等处理难题,研究设计了一种低压渐进式电催化联合破乳剂处理工艺,该渐进式电催化装置分为上中下3 区,其中电极高度分别为 5、5、15 cm,极板间距分别为 0.4、1、2 cm,可以有效避免反应器内电场分布不均匀问题.通过正交试验确定最优运行条件为:电流 20 A,电解时间 2h,破乳剂投加量 400 mg/L.最优运行条件下处理后的含聚废水出水ρ(油)≤1 000mg/L,且可以连续稳定运行,比单独使用破乳剂可降低处理成本24.64%,该工艺可以有效降低破乳剂的加药量.
Experimental research on pretreatment of polymer-containing wastewater by low pressure progressive electro-catalytic demulsification equipment
In view of the problem that polymer-containing wastewater contains high concentration of oil and hard to be demulsificated,a low pressure progressive electro-catalytic demulsification process was designed.The said progressive electro-catalytic equipment is divided into three zones:upper,middle and lower,the electrode height are 5,5,and 15 cm respectively,and the electrode plate spacing are 0.4,1 and 2 cm respectively,which can effectively avoid the uneven distribution of electric field in the reactor.Through orthogonal experiments,the optimal operating conditions are determined to be as follows:the electric current is 20 A,the electrolysis time is 2 h,the demulsifier dosage is 400 mg/L.Under the above conditions,the mass concentration of oil in the effluent water of the treated polymer-containing wastewater was not above 1 000 mg/L,and the system could operate con-tinuously and stably.Compared to using demulsifiers alone,the treatment cost of the said process reduced by 24.64%,and demulsifier dosage was also reduced effectively.

step potentialelectro-catalytic demulsificationpolymer-containing wastewatercurrentvolt-age

方伟

展开 >

长沙华时捷环保科技发展股份有限公司,长沙 410000

阶梯电位 电催化破乳 含聚废水 电流 电压

2024

工业用水与废水
东化工程科技股份有限公司

工业用水与废水

CSTPCD
影响因子:0.649
ISSN:1009-2455
年,卷(期):2024.55(1)
  • 13