首页|火试金ICP-OES法测定废线路板中的金含量及测量不确定度的评定

火试金ICP-OES法测定废线路板中的金含量及测量不确定度的评定

扫码查看
建立了火试金ICP-OES法测定废线路板中的金含量的方法。对方法进行了优化及验证。在0~2。0mg/L范围内线性关系良好,相关系数为0。999。废线路板中金的测试的平均回收率为94。5%~104%,方法的精密度为4。6%。火试金ICP-OES法测定废线路板中的金含量,测量结果为3。03 mg/kg,扩展不确定度为12%(k=2)。对不确定度贡献最大的主要分量为样品前处理过程中的消解不确定度、绘制校准曲线引入的不确定度、样品重复测定引入的不确定度。该法高效快捷、操作简便、灵敏准确,适用于废线路板中金含量的快速测定。
Determination of Gold Content in Waste Circuit Board by ICP-OES with Fire Assay and Evaluation of Measurement Uncertainty
A testing method for determination of gold content in waste circuit board by ICP-OES with fire assay was developed.The test parameters were optimized and validated.The calibration curve was linear in the range of 0 to 2.0 mg/L,and correlation coefficient was 0.999.The average recoveries of gold content were 94.5%to 104%.RSD of this method was 4.6%.The test result of gold content in waste circuit boards was determined by ICP-OES with fire assay method was 3.03 mg/kg,and the expanded uncertainty was 12%(k=2).The main components contributing most to uncertainty were the uncertainty introduced by the digestion process,the uncertainty introduced by the calibration curve fitting,and the uncertainty introduced by the repeatability measurement.The proposed method could be applied in the determination for gold content in waste circuit board,with the advantages of rapidity,simplicity,high sensitivity and accuracy.

fire assayICP-OESwaste circuit boardgold contentmeasurement uncertainty

罗平

展开 >

广东领测检测技术有限公司,广东 江门 529100

火试金 ICP-OES 废线路板 金含量 测量不确定度

2025

广州化工
广州市化工行业协会 广州市化学化工学会 广州市化学工业研究所

广州化工

影响因子:0.358
ISSN:1001-9677
年,卷(期):2025.53(1)