首页|基于常规气象观测站安装环境下的气温变化对比分析

基于常规气象观测站安装环境下的气温变化对比分析

扫码查看
[目的]由于常规气象观测站建设受管理、土地归属等限制,在选址时,部分两要素站点(气温、雨量)难以获得理想的探测环境.为研究不同安装环境对气温监测值造成的影响.[方法]选取水城区山地丘陵(顺场乡)和靠近大型水体(玉舍镇)的下垫面分别为草地(顺场站、纸厂站)、水泥地板(顺场中学、玉舍水库)共4 个常规气象观测站2023 年逐时气温数据.[结果]通过统计、对比分析发现,在山地丘陵环境条件下,下垫面为草地的顺场站升温时间比下垫面为屋顶水泥地板的顺场中学站持久,且下垫面为草地的气温比下垫面为屋顶水泥地板的气温偏高,2 种下垫面的气温差异在冬季的白天表现更为明显.在靠近大型水体环境下,夏、秋季下垫面为草地较下垫面为屋顶水泥地板呈现较高的气温峰值,受大型水体影响,玉舍水库站的升温速度和降温速度均较缓慢;2 个站点的日最高气温和日最低气温在 1 月、6 月、9 月、10 月出现了较大差值.2种环境条件下,同一下垫面的月最高气温和月最低气温较大差值主要集中在8-11 月;气温在冷热季节交换时节,同一下垫面的气温监测值差异达到最大,夏秋季高温连续时段,同一下垫面差值最小.[结论]常规气象观测站在选址建设时,应能代表周边一定范围内的气象状况,建设在平整的下垫面上.同时,需定期做好锄草、剪草等维护工作,能更好地保障监测值的准确性、代表性、比较性和连续性.
Comparison of Temperature Variation Based on the Installation Environment of Conventional Meteorological Observation Stations
Due to the limitation of management and land ownership of conventional meteorological observation stations,it is difficult for some two-element stations(temperature and precipitation)to have ideal detection environment.The installation environments of observation stations have certain influence on temperature observation data.This paper selects hourly temperature data in 2023 from four conventional meteorological observation stations,namely Shunchang Station and Paper Mill Station with grassland as underlying surface and Shunchang Middle School Station and Yushe Reservoir Station with roof cement slab as underlying surface.The four stations are located in Shunchang Township,the mountainous and hilly areas of the urban area,and Yushe Town with the underlying surface near large water bodies.Through statistical and comparative analysis,we have found that in mountainous and hilly environments,the temperature warming time of Shunchang Station is longer than that of Shunchang Middle School Station.Moreover,the temperature at Shunchang Station is higher than that at the Shunchang Middle School Station.The temperature difference between the two types of underlying surfaces is more pronounced during the daytime in winter.In environments close to large water bodies,the grassland underlying surface in summer and autumn presents a higher temperature compared to the roof cement slab underlying surface.Due to the influence of large water bodies,the heating and cooling rates of Yushe Reservoir Station are relatively slow.The daily maximum and minimum temperatures at the two stations show significant differences in January,June,September and October.Under the two different environmental conditions,the large difference between the monthly highest and lowest temperatures under the same underlying surface is mainly concentrated in the period from August to November.In the exchange period of hot and cold seasons,the difference in temperature observation values under the same underlying surface reaches its maximum.During the continuous period of high temperature in summer and autumn,the temperature difference in the same underlying surface is the smallest.In summary,the selected sites for building conventional meteorological observation stations should be able to represent the meteorological conditions within a certain range of the surrounding area.They should be built on a flat underlying surface,and the regular work of environment maintenance such as the grass weeding and cutting should be carried out to better ensure the accuracy,representativeness,comparability and continuity of observation data.

meteorological observation stationenvironmenttemperaturemonitoring contrast

陈蕴、张沪生、罗通均、耿克思、王仕超

展开 >

贵州省水城区气象局,贵州 水城 553000

贵州省气象数据中心,贵州 贵阳 550002

气象观测站 环境 气温 监测对比

2024

中低纬山地气象
贵州省气象学会

中低纬山地气象

影响因子:0.33
ISSN:2096-5389
年,卷(期):2024.48(6)