首页|基于Sagnac干涉计谐波游标效应的光纤温度传感器

基于Sagnac干涉计谐波游标效应的光纤温度传感器

扫码查看
提出一种基于双萨格奈克(Sagnac)干涉计谐波游标效应的光纤温度传感器,在该传感器中,传感干涉计中熊猫光纤的长度约为参考干涉计中熊猫光纤的整数倍。理论分析与实验结果表明,当游标放大倍率相同时,基于谐波游标效应和基于普通光学游标效应的双Sagnac干涉计具有相同的温度灵敏度,但谐波游标效应对应的熊猫光纤长度失谐量明显大于普通光学游标效应,且阶数越高对应的失谐量越大。由于失谐量越大,游标放大倍率越容易控制和实现,因此,从制备角度上讲,谐波游标效应明显优于普通光学游标效应。该研究可为后续光学游标效应的研究提供重要参考。
Fiber Optic Temperature Sensor Based on Harmonic Vernier Effect of Sagnac Interferometer
Fiber optic interferometer has the advantages of small size,light weight,anti-corrosion,anti-electromagnetic interference,high sensitivity,etc.,and is widely used in the measurement of temperature,humidity,magnetic field and other parameters.In recent years,researchers have dramatically improved the measurement sensitivity of interferometric fiber-optic sensors by cascading or paralleling two fiber-optic interferometers to produce an optical Vernier effect.When the free spectral ranges of the two fiber optic interferometers are close but not equal,the resulting Vernier effect is called the normal Vernier effect,when the free spectral range of one fiber optic interferometer is about an integer multiple of the other fiber optic interferometer,the resulting Vernier effect is called the harmonic Vernier effect.In this paper,a parallel optical fiber temperature sensor based on two Sagnac interferometers is proposed,where the interferometers SI1 and SI2 are connected to the two outputs of the fiber-optic coupler C3,where SI1 is a reference interferometer and SI2 is a sensing interferometer.When the length of the Panda fiber in the SI2 interferometer is approximately i+1 of the length of the Panda fiber in the SI1 interferometer(i is 1,2,3…)times,the two interferometers will produce an i-order harmonic Vernier effect.When i is 0,it produces an normal Vernier effect,at which time there will be a single envelope in the interference spectrum.When i is 1,it produces a first-order harmonic Vernier effect,at which time there will be a double envelope in the interference spectrum.When i is 2,it produces a second-order harmonic Vernier effect,at which time there will be a triple envelope in the interference spectrum.In other cases,the order is analogous.We have numerically simulated the theoretical analysis and the free spectral range of the interferometric spectrum of the length interferometer SI1 with a Panda fiber of 520 mm at constant temperature is 9.13 nm.The SI2 interferometers with lengths of 572 mm,953 mm,and 1 430 mm of the Panda fiber have free spectral ranges of 8.30 nm,4.98 nm,and 3.32 nm,respectively.When the temperature is increased from T0℃to T0+1℃,the interference spectra of SI2 interferometers with different Panda fiber lengths are all shifted to the short-wave direction,and the shifts are all about 1.89 nm,which is consistent with the theoretical analysis.The parallel interference spectra of interferometer SI1 and SI2 with Panda fiber lengths of 572 mm,953 mm and 1 430 mm show single,double and triple envelopes respectively,indicating that the two interferometers produce the normal Vernier effect,first-order and second-order harmonic Vernier effects,respectively,and from the theoretical calculations.It can be seen that the amplification of the normal Vernier effect,first-order and second-order harmonic Vernier effects are all 11 times.When the temperature increases from T0℃to T0+ 1℃,the single envelope moves in the short-wave direction,while the double and triple envelopes both move in the long-wave direction,which is opposite to that of the single SI2.In addition,the shifts of the single,double and triple envelopes are all about 20.7 nm due to the fact that the Vernier magnification is the same for the normal Vernier effect,first-order and second-order harmonic Vernier effects.It is experimentally concluded that the interference spectra of SI2 are blueshifted in the temperature range from 40℃to 50℃,and the shifts are all about 1.89 nm,which is consistent with the theoretical analysis and simulation results.The temperature sensitivity of the sensor corresponding to the normal Vernier effect is-20.67 nm/℃,the temperature sensitivity of the sensor corresponding to the first-order harmonic Vernier effect is 21.34 nm/℃,the temperature sensitivity of the sensor corresponding to the second-order harmonic Vernier effect is 21.18 nm/℃,and the fiber optic sensors corresponding to the harmonic Vernier effect and the normal Vernier effect have almost the same temperature sensitivities,which are both about 21 nm/℃.This results are consistent with the theoretical analysis and simulation results.The above experimental results show that the temperature sensitivity of the SI2 interferometer is independent of the length of the Panda fiber,although the magnification is the same,the harmonic Vernier effect and the normal Vernier effect correspond to the detuning of the length of the Panda fiber are obviously different,the detuning corresponding to the normal Vernier is 52 mm,and the detuning corresponding to the first-order and second-order harmonics is-87 mm and-130 mm,respectively.This shows that the higher the order,the larger the detuning amount,which is approximately a multiple increase.The above experimental results are consistent with the theoretical analysis.Since the larger the detuning amount,the easier the Vernier magnification can be controlled and realised,the harmonic Vernier effect is obviously superior to the normal Vernier effect from the preparation point of view.This study can provide an important reference for the subsequent study of optical Vernier effect.

Optical fiber sensorSagnac interferometerHarmonic Vernier effectNormal Vernier effectTemperature sensing

杨玉强、张钰颖、李雨婷、高佳乐、牟小光、毕磊

展开 >

广东海洋大学 深圳研究院,深圳 518120

广东海洋大学 广东省南海海洋牧场智能装备重点实验室,湛江 524088

广东海洋大学 智慧海洋传感网及其装备工程技术研究中心,湛江 524088

广东海洋大学 机械工程学院,湛江 524088

广东海洋大学 继续教育学院,湛江 524088

展开 >

光纤传感器 Sagnac干涉计 谐波游标效应 普通游标效应 温度传感

广东省自然科学基金面上项目广东省自然科学基金面上项目深圳市基础研究面上项目深圳市基础研究面上项目广东省普通高等学校重点领域专项广东海洋大学科研启动基金

2023A15150112122022A1515011603JCYJ20210324122813036JCYJ202205301622000012021ZDZX1015060302112009

2024

光子学报
中国光学学会 中国科学院西安光学精密机械研究所

光子学报

CSTPCD北大核心
影响因子:0.948
ISSN:1004-4213
年,卷(期):2024.53(4)
  • 20