针对5G共址建设中遇到的外市电需求缺口小,外电扩容改造引入困难、成本高、周期长的基站站点,设计了一套电源控制系统,包含主控模块、电源模块、温度采集模块、电流采集模块等.该系统可以通过采集机房内温度及用电信息,分析机房原有电缆载流量情况,根据需要控制空调运行数量、蓄电池充放电及通信设备的供电方式,以期达到精细化管理机房电能的目的,从而实现降本增效,缩短5G网络建设周期.
Design of the Power Control System for the Base Station
A power supply control system is designed to meet the needs of 5G co-location,such as small demand gap,difficulty,high cost and long period of base station,including the main con-trol module,power module,temperature acquisition module,current acquisition module.The system can collect the temperature and electricity information in the computer room,analyze the current-carrying capacity of the existing cables in the computer room,control the air-condition-ing operation quantity,charge and discharge of the storage battery and the power supply of the communication equipment according to the need,in order to achieve the goal of fine manage-ment of power room,thereby reducing costs and efficiency,shorten the 5G network construc-tion cycle.