首页|低温余热发电在己内酰胺项目中的应用

低温余热发电在己内酰胺项目中的应用

扫码查看
基于当前己内酰胺装置蒸汽消耗大,蒸汽凝液余热未完全利用的现状,以600 kt/a己内酰胺装置为例,介绍了低温余热发电在己内酰胺装置中的应用及节能效果.结果表明:600 kt/a己内酰胺装置蒸汽消耗量约 1 020 t/h,蒸汽凝液回收总量约 870 t/h,在保证装置冷冻水对蒸汽凝液需求的同时,充分利用蒸汽凝液作为热源,采用有机朗肯循环(ORC)低温余热发电系统,以 1,1,1,3,3-五氟丙烷作为有机工质进行低温余热发电,发电系统运行稳定、安全,每年净发电量达 1.784×107 kW·h,相当于减少标煤消耗 5 607 t,减少CO2 减排量10 601 t,同时可节约循环水量 1.440×107 t,节能和经济效果显著.
Application of low-temperature waste heat power generation in caprolactam project
Based on the current situation of high steam consumption and incomplete utilization of waste heat from steam conden-sate in caprolactam units,taking a 600 kt/a caprolactam unit as an example,the application and energy-saving effect of low-tem-perature waste heat power generation were introduced in caprolactam units.The results showed that the steam consumption of the 600 kt/a caprolactam unit was about 1 020 t/h and the total amount of steam condensate recovery was about 870 t/h,so an organic Rankine cycle(ORC)low-temperature waste heat power generation system was adopted using 1,1,1,3,3-pentafluoropro-pane as the organic working medium in order to fully utilize the steam condensate as heat source while ensuring the demand for steam condensate from the unit's chilled water;and the power generation system operated stably and safely and provided significant energy-saving and economic effects,which produced an annual net power generation of 1.784×107 kW·h,equivalent to reducing the consumption of standard coal by 5 607 t and CO2 emissions by 10 601 t and saving circulating water by 1.440×107 t.

low-temperature waste heat power generationorganic Rankine cyclecaprolactamsteamenergy-saving

徐浩

展开 >

中石化湖南石油化工有限公司,湖南 岳阳 414000

低温余热发电 有机朗肯循环 己内酰胺 蒸汽 节能

2024

合成纤维工业
中国石化集团巴陵石油化工有限责任公司 中国石化集团公司合成纤维科技情报中心站

合成纤维工业

CSTPCD
影响因子:0.417
ISSN:1001-0041
年,卷(期):2024.47(4)
  • 8