华东电力2014,Vol.42Issue(5) :893-897.

考虑N-1-1停运标准的城市电网结构

Urban Power Grid Structure Considering the N-1-1 Outage Standard

张琪祁 冯煜尧 欧阳帆 苏运
华东电力2014,Vol.42Issue(5) :893-897.

考虑N-1-1停运标准的城市电网结构

Urban Power Grid Structure Considering the N-1-1 Outage Standard

张琪祁 1冯煜尧 1欧阳帆 1苏运1
扫码查看

作者信息

  • 1. 国网上海市电力公司电力科学研究院,上海 200437
  • 折叠

摘要

城市电网是电力系统主要的负荷中心,N-1-1停运下的电网供电能力是城网可靠性的重要内容.对比了国内外部分先进地区对城市电网N-1-1停运下的供电可靠性要求,分析了城网中变电站内和站间联络结构对N-1-1停运后供电能力的影响,讨论了满足英国ER P2/6导则N-1-1标准的城网结构,在此基础上提出了适用于城网进一步发展的更加严格的N-1-1停运供电可靠性标准及相应结构.

Abstract

Urban power grid is a major load center of power system.The power supply capacity in N-1-1 outage is the important part of the urban network reliability.This paper compares the grid reliability requirements in N-1-1 outage of some developed urban areas in China and abroad,and analyzes the impact of the intra-and intersubstation contact structure on power supply capacity during N-1-1 outage.In addition,the urban network structure which can meet the N-1-1 standard of British ER P2/6 guideline is discussed,and thereupon a more stringent N-1-1 standard and corresponding network structure is proposed to accommodate the development of urban power grid.

关键词

城市电网/供电可靠性/N-1-1停运/电网结构/标准

Key words

urban power grid/power supply reliability/N-1-1 outage/grid structure/standard

引用本文复制引用