首页|基于电压增量的变压器和应涌流辨别新算法

基于电压增量的变压器和应涌流辨别新算法

扫码查看
和应涌流出现后可能造成变压器差动保护误动作,影响变压器正常运行,但是目前专门对和应涌流情况进行有效识别的方法还很少.通过对运行变压器带负载的情况进行误动仿真分析,找出和应涌流和CT暂态饱和的共同作用是导致变压器差动保护误动的根本原因;并依据和应涌流导致变压器差动保护误动期间变压器端电压缓慢升高,而内部故障时变压器端电压降低的变化趋势特点,提出一种基于电压增量的变压器和应涌流辨别的新算法,通过大量仿真实验,验证了新算法的有效性和可行性.
A New Algorithm for Transformer Sympathetic Inrush Identification Based on Voltage Increment
Sympathetic inrush may cause mal-operation of transformer differential protection,and affect the normal transformer operation,but at present there are few effective methods to identify sympathetic inrush.The malfunction simulation analysis of the on-load operation of transformer indicates that the interaction between inrush transient saturation and CT transient saturation result in the transformer differential protection mal-operation.Considering that the transformer terminal voltage rises slowly during the mal-operation,but drops during internal fault,this research puts forward a new algorithm for transformer sympathetic inrush identification based on voltage increment.A large number of simulation experiments have verified its effectiveness and feasibility.

sympathetic inrushon-load runningCT transient saturationvoltage increment