Reason Analysis and Suggestions for 2013 Shanghai Area Power Boiler "Four Tubes" Leakage
This paper summarizes the cause analysis of power generation boiler "Four Tubes" leakage for 2013 Shanghai Grid,by comparing the leakage frequency and causes with those of 2012.In view of the status quo of " Four Tubes" leakage in Shanghai power grid,some suggestions are proposed about how to reduce and prevent the boiler explosion times,eliminate potential safety problems,and ensure safe boiler operation.
power boiler"Four Tubes"leakage analysissuggestions