首页|气冷堆进水事故分析

气冷堆进水事故分析

Analysis on Water Ingress Accident of a Gas Cooled Reactor

扫码查看
气冷堆受工作环境或运行状态影响,可能发生其所特有且造成严重事故后果的进水事故.针对美国气冷堆S4堆设计方案,模拟分析在正常运行工况下冷凝器部分传热管破裂导致的进水事故,研究事故造成的正反应性引入、回路超压等事故后果.利用反应堆蒙特卡洛程序RMC计算进水过程中谱移吸收体材料Ir对反应性引入的影响,并利用自主研发的气冷堆系统分析程序HXRTRAN计算进水过程中的温度及布雷顿循环回路压强数据.结果表明,进水事故发生时,0.5 kg进水量将导致布雷顿循环回路的压强超过10 MPa,可能会造成更大面积的冷凝器管路破损并导致水二次灌入;同时进水将导致大量正反应性引入,若堆内燃料表面添加了谱移吸收体材料Ir,堆芯可在进水事故下自发降功率,当水蒸气量超过5 kg后,堆芯功率快速下降至额定功率的2.2%左右,并逐渐接近停堆.可见谱移吸收体材料Ir对于堆芯进水导致的正反应性引入具有显著的抑制效果.
The gas cooled reactor is featured with high inherent safety,small size,and a simple start-up process.However,the water ingress accident might occur due to the influence of the working environment or operating status.Based on the design scheme of the Submersion-Subcritical Safe Space(S4)reactor,this work simulated and analyzed the water ingress accident caused by the rupture of the heat transfer tube of the condenser under normal operating conditions,and studied the accident consequences such as the introduction of positive reactivity,the overpressure of the Brayton cycle.This work calculated the influence of spectral shift materials on reactivity introduction during the water ingress process with the Reactor Monte Carlo code RMC.And the temperature and Brayton cycle pressure were calculated during the water ingress process with the gas cooled reactor transient analysis code,HXRTRAN.The results show that when a water ingress accident occurs,0.5 kg water ingress causes the pressure of the Brayton cycle to exceed 10 MPa,which may lead to larger damage to the condenser pipeline and secondary seawater injection.Meanwhile,water ingress may lead to a large amount of positive reactivity introduction.If spectral shift absorbers,Ir,are added to the fuel surface in the reactor,the core may reduce power or even subcritical shutdown spontaneously in the water ingress accident.When the amount of water vapor exceeds 5 kg,the core power quickly decreases to about 2.2%FP and gradually approaches shutdown.Therefore,the spectral shift materials,Ir,have a significant inhibition effect on the introduction of positive reactivity caused by water ingress of the core.

Gas cooled reactorWater ingress accidentPositive reactivity introduction

马誉高、曹忠彬、王金雨、邓坚、鲍辉、丁书华、程坤、胡文桢

展开 >

中国核动力研究设计院核反应堆系统设计技术重点实验室,成都,610213

气冷堆 进水事故 正反应性引入

2024

核动力工程
中国核动力研究设计院

核动力工程

CSTPCD北大核心
影响因子:0.3
ISSN:0258-0926
年,卷(期):2024.45(2)