首页|稳压器波动管接管与底封头焊缝相控阵超声检测技术研究

稳压器波动管接管与底封头焊缝相控阵超声检测技术研究

Research on Phased Array Ultrasonic Inspection Technology for the Pressurizer Surge Nozzle to Vessel Weld

扫码查看
核电厂稳压器波动管接管与底封头焊缝结构的特殊性引起单侧可达和球形检测面导致较大定位偏差的问题,针对这2个问题研发相控阵超声检测(PAUT)技术与缺陷定位修正算法,并在带自然缺陷的模拟试块上进行验证与射线检测结果对比.结果表明,结合缺陷定位修正算法,PAUT技术满足能力验证的要求,检出能力与射线检测相当.
In response to the single-sided accessibility issue caused by the weld structure and the significant positioning deviation caused by spherical detection surface in the surge nozzle to vessel weld of pressurizer in nuclear power plant,a phased array ultrasonic inspection(PAUT)technology and a defect positioning correction algorithm are developed,which are verified in a simulated body with natural defects and compared with the results of radiographic inspection.The results show that,combined with the defect positioning correction algorithm,the PAUT technology meets the requirements of the performance demonstration,and the detection capability is equivalent to that of radiographic inspection.

Surge nozzle to vessel weldSpherical detection surfacePositioning correctionPhased array ultrasonic testing(PAUT)

罗立群、朱佳震、陈均、康志平

展开 >

大亚湾核电运营管理有限责任公司,广东 深圳,518000

中广核检测技术有限公司,江苏苏州,215004

国家核电厂安全及可靠性工程技术研究中心,江苏苏州,215004

波动管接管与底封头焊缝 球形检测面 定位修正 相控阵超声检测(PAUT)

2024

核动力工程
中国核动力研究设计院

核动力工程

CSTPCD北大核心
影响因子:0.3
ISSN:0258-0926
年,卷(期):2024.45(5)