首页|特高压换流站交流滤波电容组件电热特性分析

特高压换流站交流滤波电容组件电热特性分析

扫码查看
针对稳态运行下高次谐波对特高压换流站交流滤波电容组件造成的严重发热问题,为设备状态分析和老化评估提供依据,以BP11/13型双调谐滤波器电容塔为例,建立了电容塔和薄膜电容器有限元模型.首先采用电热耦合方法,给定电容塔谐波电流幅值和频率,计算电容塔的电热特性,与换流站测量数据进行对比,验证了有限元模型的准确性,发现了电容塔发热严重的薄弱部位为中层电容器.然后对薄膜电容器元件进行精细化建模,研究了薄膜电容器铜损和介质损耗的特点,分析了薄膜电容器的发热来源为金属电极和电介质.最后,指出了电容组件的易损区域,提出了应重点关注和保护的部位,并给出提高设备安全和稳定性的建议.
Analysis of Electrothermal Characteristics of AC Filter Capacitor Components in Ultra Voltage Converter Station
Aiming at the serious heating problem caused by high-order harmonics on AC filter capacitor components of ultra high voltage converter stations under steady-state operation,to provide a basis for equipment status analysis and aging evalua-tion,finite element models of capacitor towers and thin film capacitors were established taking the BP11/13 dual tuned filter ca-pacitor tower as an example.Firstly,by using the electric thermal coupling method,the electric thermal characteristics of the ca-pacitor tower were calculated by providing harmonic current amplitude and frequency for the capacitor tower,and compared with the measurement data of the converter station to verify the accuracy of the finite element model.It was found that the weak part of the capacitor tower with severe heating was the middle layer capacitor.Afterwards,fine modeling was carried out on the thin film capacitor components,and the characteristics of copper loss and dielectric loss in thin film capacitors were studied.The sources of heat generation in thin film capacitors were analyzed to be metal electrodes and dielectrics.Finally,the vulnerable are-as of the capacitor components were figured out,and the parts that should be given special attention and protection were pro-posed.Suggestions to improve the safety and stability of equipment are also given.

UHVDCAC filtercapacitor towerfilm capacitor

李林卓、周国伟、孙启贺、孙海峰

展开 >

华北电力大学电力工程系,河北保定 071003

国网浙江省电力有限公司超高压分公司,浙江 杭州 310007

特高压直流输电 交流滤波器 电容塔 薄膜电容器

2024

河北电力技术
河北省电机工程学会,河北省电力研究院

河北电力技术

影响因子:0.306
ISSN:1001-9898
年,卷(期):2024.43(6)