首页|介质阻挡放电等离子体协同Fe2+降解水中萘普生

介质阻挡放电等离子体协同Fe2+降解水中萘普生

扫码查看
文章利用介质阻挡放电(dielectric barrier discharge,DBD)等离子体与Fe2+协同降解水中萘普生(NPX),并与单一 DBD等离子体体系进行比较.分别探究Fe2+浓度、放电功率、初始pH值及天然有机物(natural organic matter,NOM)的质量浓度对NPX去除效果的影响.采用液质联用技术分析NPX降解产物,并使用毒性评估软件工具(Toxicity Estimation Software Tool,T.E.S.T.)分析预测产物的生物毒性.结果表明:在介质阻挡放电等离子体协同Fe2+体系中,当Fe2+浓度为200 μmol/L、放电功率为71 W、初始pH值为4.0时NPX去除效果最好,而水中NOM的存在会抑制NPX的降解.NPX降解过程较符合准一级反应动力学模型,检测出7种中间产物,提出可能的降解路径.生物毒性预测结果表明,NPX在降解过程中会生成毒性更高的产物.
Degradation of naproxen in aqueous solution by dielectric barrier discharge plasma combined with Fe2+
In this paper,the co-degradation of naproxen(NPX)in aqueous solution by dielectric barrier discharge(DBD)plasma combined with Fe2+was studied and compared with a single DBD plasma sys-tem.The effects of Fe2+concentration,discharge power,initial pH value and natural organic matter(NOM)concentration on the removal effect of NPX were investigated.The NPX degradation products were analyzed by liquid chromatography time-of-flight mass spectrometry,and the Toxicity Estima-tion Software Tool(T.E.S.T.)was used to evaluate the biological toxicity of NPX degradation prod-ucts.The results show that the removal effect of NPX is the best when the concentration of Fe2+is 200 μmol/L,the discharge power is 71 W and the initial pH value is 4.0,and the presence of NOM in aqueous solution will inhibit the degradation of NPX.The degradation process of NPX is consistent with the quasi-first-order reaction kinetics model.Seven intermediate products were detected and the possible degradation paths were proposed.The results of biological toxicity prediction show that NPX will produce more toxic products during degradation.

dielectric barrier discharge(DBD)Fenton reactionnaproxen(NPX)degradation

叶正新、胡淑恒、许子牧、程诚

展开 >

合肥工业大学资源与环境工程学院,安徽合肥 230009

中国科学院等离子体物理研究所,安徽合肥 230031

介质阻挡放电(DBD) Fenton反应 萘普生(NPX) 降解

国家自然科学基金国家自然科学基金合肥工业大学博士点专项研究基金

5177720651807046JZ2017HGBZ0944

2024

合肥工业大学学报(自然科学版)
合肥工业大学

合肥工业大学学报(自然科学版)

CSTPCD北大核心
影响因子:0.608
ISSN:1003-5060
年,卷(期):2024.47(5)