Based on cone penetration test(CPT)data of the clay layer in Hefei City,a soil profile ran-dom field model was established to explore the influence of linear and nonlinear detrending on the cal-culated scale of fluctuation of soil properties.Linear and nonlinear detrending methods were used to detrend the original CPT data,and the stationary and ergodic tests were performed on the obtained fluctuation components.Correlation function method and spatial recursion method were used to calcu-late the scale of fluctuation of soil properties corresponding to the fluctuation components.The sensi-tivity of calculation methods and sampling spacing to different detrending methods was discussed.The results show that for the data with nonlinear trend,linear detrending will make the stability of the ob-tained fluctuation components worse,resulting in the increase of the mean value,standard deviation and coefficient of variation of the final calculated scale of fluctuation,and the stability of the calculated results is obviously worse.Compared with linear detrending,nonlinear detrending has better adapta-bility.In addition,the sensitivity of the correlation function method to different detrending methods is greater than that of the spatial recursion method,and the sampling spacing does not affect the overall trend of the data and the choice of the detrending method.