摘要

尿素水解器作为烟气脱硝系统中的关键设备,其稳定运行对整个系统的性能至关重要."虚假液位"的产生不仅影响尿素水解器的运行效率,还可能导致系统发生安全事故.因此,文章简述了尿素水解制氨工艺的原理、流程、危害,重点介绍了某超超临界百万机组尿素水解器产生"虚假液位"的过程及现象,并分析了产生"虚假液位"的原因及采取的措施,总结了尿素水解器日常运行中防止"虚假液位"发生的防范措施.

Abstract

The urea hydrolyzer as a key equipment in the flue gas denitrification system,its stable operation is very important to the performance of the whole system.The generation of"false liquid level"not only affects the operating efficiency of the urea hydrolyzer,but also may lead to safety incidents in the system.Therefore,this paper briefly describes the principle,process and hazards of urea hydrolysis process for ammonia production,focuses on the process and phenomenon of"false water level"generated by urea hydrolyzer of an ultra-supercritical million unit,and analyzes the causes of"false liquid level"and the measures taken,summarizes the preventive measures to prevent the occurrence of"false liquid level"in the daily operation of urea hydrolyzer.

关键词

烟气脱硝/尿素/"虚假液位"/水解器

Key words

flue gas denitrification/urea/"false liquid level"/hydrolyzer