首页|某污水处理厂水质指标的监测与处理效果分析及评价

某污水处理厂水质指标的监测与处理效果分析及评价

扫码查看
某污水处理厂肩负着该市工业以及生活污水处理的重任,对某污水处理厂的水质指标进行监测,并对污染物的去除效果进行分析及评价.结果表明:某污水处理厂对污水进行处理后,pH为7.18~7.62;COD为10~27 mg/L,出口COD去除率为88%~95%;BOD5为1~7.5 mg/L,BOD5去除率为90%~97%;氨氮浓度为0.7~2.5 mg/L,NH3-N去除率为90%~97%;TN浓度范围10~13 mg/L,TN去除率为75%~80%;TP浓度为0.2~0.4 mg/L,TP去除率为83%~88%.通过与GB 18918-2002《城镇污水处理厂污染物排放标准》中一级B标准规定的最高允许排放浓度标准值比较,该污水处理厂各污染物浓度均达到标准要求,且处理效果比较稳定.
Monitoring and Treatment Effect Analysis and Evaluation of Water Quality Indicators in a Certain Sewage Treatment Plant
A certain sewage treatment plant shoulders the heavy responsibility of industrial and domestic sewage treatment in the city.Therefore,this article monitors the water quality indicators of a certain sewage treatment plant,analyzes and evaluates the removal effect of pollutants by the plant.The results showed that a certain sewage treatment plant had a pH value between 7.18 and 7.62 after treating the sewage;The COD concentration is between 10~27 mg/L,and the removal rate of COD by the outlet is between 88%and 95%;The concentration of BOD5 is between 1~7.5 mg/L,and the removal rate of BOD5 is between 90%and 97%;The ammonia nitrogen concentration is between 0.7 and 2.5 mg/L,and the removal rate of NH3-N is between 90%and 97%;The concentration range of TN is between 10 mg/L and 13 mg/L,and the removal rate of TN is between 75%and 80%;The TP concentration is between 0.2 and 0.4 mg/L,and the removal rate of TP is between 83%and 88%.By comparing with the maximum allowable emission concentration standard value specified in the first Class B standard of GB 18918-2002"Pollutant Discharge Standards for Urban Sewage Treatment Plants",the concentration of all pollutants in the sewage treatment plant meets the standard requirements and the treatment effect is relatively stable.

sewage treatment plantwater quality indicatorsmonitoringeffect analysis

朱锦芬

展开 >

茂名市茂南生态环境监测站,广东 茂名 525000

污水处理厂 水质指标 监测 效果分析

2024

化工生产与技术
巨化集团公司

化工生产与技术

影响因子:0.209
ISSN:1006-6829
年,卷(期):2024.30(4)