化工设计通讯2024,Vol.50Issue(1) :25-27.

催化裂化装置富气压缩机级间冷却器改造

Retrofit of Interstage Cooler for Rich Gas Compressor in Catalytic Cracking Unit

席欢欢 韩晨阳 冯蕾博
化工设计通讯2024,Vol.50Issue(1) :25-27.

催化裂化装置富气压缩机级间冷却器改造

Retrofit of Interstage Cooler for Rich Gas Compressor in Catalytic Cracking Unit

席欢欢 1韩晨阳 1冯蕾博1
扫码查看

作者信息

  • 1. 陕西延长石油(集团)有限责任公司延安炼油厂,陕西延安 727406
  • 折叠

摘要

陕西延长石油(集团)有限公司延安炼油厂100万t/a催化裂化装置富气压缩机级间冷却器管束泄漏频繁,使用周期较短,影响装置长周期运行.通过对管束泄漏原因进行分析,制定改进措施,对级间冷却器进行改造,改造后使用效果明显,满足了装置长周期运行需求.

Abstract

The inter stage cooler tube bundle of the rich gas compressor in the 1 million ton/year catalytic cracking unit of Yanan Refinery of Shaanxi Yanchang Petroleum(Group)has frequent leakage and short service life,which affects the long-term operation of the unit.By analyzing the causes of tube bundle leakage,developing improvement measures,and modifying the inter stage cooler,the use effect of the modification is obvious,meeting the long-term operation needs of the unit.

关键词

级间冷却器/管束内漏/改造

Key words

interstage cooler/tube bundle internal leakage/modification