化工设计通讯2024,Vol.50Issue(5) :61-63.

冷氢化装置三级换热器失效的分析及措施

Analysis and Measures for the Failure of the Third Stage Heat Exchangers in the Cold Hydrogenation Device

柯曾鹏 陈维平 葛蒙
化工设计通讯2024,Vol.50Issue(5) :61-63.

冷氢化装置三级换热器失效的分析及措施

Analysis and Measures for the Failure of the Third Stage Heat Exchangers in the Cold Hydrogenation Device

柯曾鹏 1陈维平 1葛蒙1
扫码查看

作者信息

  • 1. 华陆工程科技有限责任公司,陕西西安 710065
  • 折叠

摘要

在对S31608换热管在冷氢化装置中的失效原因进行研究分析,结果表明换热管失效主要为应力和腐蚀性介质Cl共同作用引起的应力腐蚀开裂而失效.

Abstract

This article studies and analyzes the failure causes of S31608 heat exchange tubes in the cold hydrogenation device.The results indicate that the failure of heat exchange tubes is mainly caused by the stress corrosion cracking caused by the joint action of stress and corrosive medium Cl.

关键词

四氯化硅/冷氢化/换热管/失效/应力腐蚀

Key words

tetrachlorosilicon/cold hydrogenation/heat exchange tubes/invalidation/stress corrosion