As a key component of polyethylene production,the structural design and performance analysis of a large degassing chamber were crucial.A finite element model of a large degassing chamber cone and internal flow modification was established using ANSYS software to simulate the displacement deformation and stress distribution of the degassing chamber cone and internal flow modification fluid under fluid load conditions,and strength verification was carried out on key positions of the equipment.The results showed that finite element analysis improved the accuracy of traditional empirical design and verified that the designed structure meets the strength requirements under operating conditions.
关键词
脱气仓/有限元/强度/聚乙烯
Key words
Degassing chamber/Finite element method/Strength/Polyethylene