目的 探究B超引导下臂丛神经阻滞麻醉的效果.方法 随机选取2021年7月—2023年7月成武县人民医院收治的100例实施麻醉的上肢骨折手术患者为研究对象,以随机数表法分成参照组与研究组,各50例.参照组采取肌间沟臂丛神经阻滞麻醉,研究组采取B超引导下臂丛神经阻滞麻醉.比较两组患者的临床镇静评分(Ramsay Sedation Scale,Ramsay)、阻滞起效时间、完全阻滞时间、神经阻滞程度、镇痛维持时间、阻滞消退时间、循环系统功能以及不良反应发生情况.结果 研究组患者的Ramsay评分、血氧饱和度(Oxy-gen Saturation,SpO2)水平、镇痛维持时间优于参照组,差异有统计学意义(P均<0.05);研究组阻滞起效时间、完全阻滞时间、舒张压(Diastolic Blood Pressure,DBP)及心率(Heart Rate,HR)水平、阻滞消退时间均优于参照组,差异有统计学意义(P均<0.05).研究组患者的神经阻滞程度Ⅰ级高于参照组,神经阻滞程度Ⅱ级与Ⅲ级均低于参照组,差异有统计学意义(P<0.05);研究组患者的不良反应总发生率为2.00%,低于参照组的16.00%,差异有统计学意义(χ2=4.396,P<0.05).结论 B超引导下的臂丛神经阻滞麻醉在手术中的应用具有高度的精准性、安全性和可控性,为医生提供了更可靠的术中引导,同时也减少了辐射暴露的风险.
Clinical Effect of Brachial Plexus Block Anesthesia Guided by B-ultrasound
Objective To explore the effect of brachial plexus block anesthesia guided by B-ultrasound.Methods A total of 100 patients undergoing anesthesia for upper limb fracture surgery admitted to Chengwu County People's Hos-pital from July 2021 to July 2023 were randomly selected as the study objects,and they were divided into the refer-ence group and the study group by random number table method,with 50 cases in each group.The reference group re-ceived brachial plexus block anesthesia,and the study group received brachial plexus block anesthesia guided by B-ultrasound.The clinical Ramsay Sedation Scale(Ramsay),onset time of block,complete block time,nerve block de-gree,analgesic maintenance time,block resolution time,circulatory system function and the occurrence of adverse re-actions were compared between the two groups.Results Ramsay score,oxygen saturation(SpO2)level and analgesia maintenance time in study group were better than those in reference group,and the differences were statistically sig-nificant(all P<0.05).The onset time of block,complete block time,diastolic blood pressure(DBP),heart rate(HR)and block resolution time of the study group were better than those of the reference group,and the differences were statistically significant(all P<0.05).The degree of nerve block in grade Ⅰ was higher than that in the reference group,and the degree of nerve block in grade Ⅱ and grade Ⅲ was lower than that in the reference group,and the difference was statistically significant(P<0.05).The total incidence of adverse reactions in the study group was 2.00%,lower than that in the reference group(16.00%),and the difference was statistically significant(χ2=4.396,P<0.05).Conclu-sion The application of brachial plexus block anesthesia guided by B-ultrasound in surgery has a high degree of accu-racy,safety and controllability,which provides doctors with more reliable intraoperative guidance and reduces the risk of radiation exposure.

Upper extremity surgeryAnesthesiaB-ultrasoundBrachial plexus blockAdverse reaction

张桂菊、李玉显、胜海峰

展开 >

成武县人民医院麻醉科,山东菏泽 274200

上肢手术 麻醉 B超 臂丛神经阻滞 不良反应

2024

中外医疗
卫生部医院管理研究所 二十一世纪联合创新医药科学研究院

中外医疗

影响因子:0.909
ISSN:1674-0742
年,卷(期):2024.43(10)
  • 13