High voltage electrical products of new energy vehicles have the characteristics of self heating and self cooling liquid circulation,and their temperature effect is different from conventional low-voltage electrical appliances.They cannot be tested according to environmental reliability test methods such as GB/T28046 for electrical and electronic equipment.This article grasps the temperature distribution of high-pressure products with liquid cooling circulation by building a test bench.And establish a reliability testing method that matches the cooling night temperature.