在放射治疗中为保证病人受照剂量的准确性,通常需要进行治疗前的计划验证,水箱被广泛应用来实现这一目的.但现有剂量验证水箱只能用于水平、垂直和45°束线的治疗终端,且验证效率低下,无法满足当前先进的旋转Gantry治疗终端的多角度剂量验证需求.为满足Gantry治疗终端的多方位照射的束流检测要求,开发了一种可用于多角度束线剂量验证的三维水箱.经水平束线测试和相关技术验证,该水箱可以通过测量束流在不同深度处的横向剖面剂量分布,从而获得笔形束在水中的三维剂量分布,为治疗计划提供参数依据,提高常规质量保证(Quality Assurance,QA)效率;同时该水箱结构可靠,三维运动机构精度高,整个测量装置可绕治疗头的等中心点旋转,实现多角度的剂量验证,满足Gantry治疗终端中多方位照射中的束流检测要求.
Development of a 3D dose distribution validation water tank for rotating Gantry treatment terminals
[Background]In order to ensure the accuracy of the dose received by the patient in radiotherapy,it is usually necessary to verify the plan before treatment,and the water tank is widely used to achieve this purpose.However,the existing dose validation tanks can only be used for beam therapy terminals with horizontal,vertical and 45° angles,which cannot meet the multi-angle dose validation requirements of the advanced rotary Gantry beamline treatment rooms.[Purpose]This study aims to develop a three-dimensional(3D)water tank for multi-angle beam dose verification,so as to meet the beam detection requirements of multi-direction beam irradiation of gantry beam line.[Methods]The water tank box was constructed from Polymethyl Methacrylate(PMMA)and driven by the motor to rotate around the isocenter.Solidworks Simulation software package was employed to simulate the structure of the water tank,and the motion accuracy of the 3D motion mechanism was evaluated.The lateral profile dose distribution of the beam at different depths in the water was measured by a multi-strip ionization chamber(MSIC),and a 3D dose distribution of the pencil beam was obtained by stacking the profile dose distribution measured at different depths.The measurement results were compared with data obtained from commercial PTW water tank.[Results]Evaluation results show that,the maximum position error of the probe is 0.132 mm when the probe is moving in the depth direction,the maximum position error of the probe is 0.24 mm in the Y and Z directions for the probe position adjustment,and the dose measurement deviation is 0.5%±1.18%.[Conclusions]The water tank proposed in this study can quickly and accurately provide the 3D dose distribution of a pencil beam,hence,provide basic data for treatment planning systems and improve the efficiency of regular quality assurance practice.The whole measuring device can be rotated around the isocenter of the treatment head,meeting the beam detection requirements of multi-directional irradiation in the Gantry treatment rooms.

Heavy ion medical machineMulti-strip ionization chamber3D water tankQuality assuranceGantry beamline treatment rooms

康新才、罗发明、李有堂、徐治国、毛瑞士、赵祖龙、陈玉聪

展开 >

中国科学院近代物理研究所 兰州 730000

兰州理工大学 兰州 730050

中国科学院大学 北京 100049

重离子治癌加速器 分条电离室 三维水箱 质量保证 Gantry治疗终端

2025

核技术
中国核学会 中国科学院上海应用物理研究所

核技术

北大核心
影响因子:0.299
ISSN:0253-3219
年,卷(期):2025.48(1)