首页|Probe design for measuring total temperature of combustor outlet based on water cooling

Probe design for measuring total temperature of combustor outlet based on water cooling

扫码查看
To obtain the outlet temperature of combustor,a kind of high-temperature and water cooling thermocouple was designed.The main factors affecting the results of thermocouple measurement were analyzed after numerical simulation.Results showed that the high-temperature water cooling thermocouple can achieve high temperature measurement under the condition of 2 400 K.With the increase of the distance between the water cooling structure and the stagnation cover,the temperature measurement result was more accurate,and the increase in the area ratio of the inlet and outlet of the stagnation cover within a reasonable range can make the measurement results more accurate.The surface emissivity of the measuring point had a great influence on the radiation error.The pressure and flow rate of cooling water can be effectively reduced after adding zirconia coating onto the surface of the rake body.

probetotal temperaturecombustion chamberwater coolingthermocouple

ZHAO Kai、LI Feng、L(U) Fuguo、ZHOU Tao、YANG Hongyu

展开 >

School of Energy and Power Engineering,Beijing University of Aeronautics and Astronautics, Beijing 100191, China

School of Aviation Operations and Services,Aviation University of Air Force, Changchun 130022, China

National Natural Science FoundationAviation Power Fund

9174110013614B090310

2018

航空动力学报
中国航空学会

航空动力学报

CSTPCDCSCD北大核心EI
影响因子:0.59
ISSN:1000-8055
年,卷(期):2018.33(9)
  • 1