航空动力学报2024,Vol.39Issue(7) :169-176.DOI:10.13224/j.cnki.jasp.20220212

燃气分析法测量小尺寸全环燃烧室出口温度场

Outlet temperature field measurement for small annular combustor by gas analysis

资海林 马瑛 张阳 李维 张险
航空动力学报2024,Vol.39Issue(7) :169-176.DOI:10.13224/j.cnki.jasp.20220212

燃气分析法测量小尺寸全环燃烧室出口温度场

Outlet temperature field measurement for small annular combustor by gas analysis

资海林 1马瑛 1张阳 1李维 1张险1
扫码查看

作者信息

  • 1. 中国航发湖南动力机械研究所,湖南株洲 412002
  • 折叠

摘要

为探索燃气分析法测量小尺寸全环燃烧室出口温度场的应用,介绍了适应小尺寸全环燃烧室出口通道高度的多点非混合式水冷燃气取样探针设计,燃烧室出口分别布置2支5点非混合式水冷燃气取样探针和双铂铑热电偶,随位移机构旋转180°,实现正、反双向数据采集,测量二氧化碳(CO2)、一氧化碳(CO)和未燃碳氢化合物(UHC)3种组分的体积分数进而计算燃气温度.试验结果表明:燃气分析法与热电偶法测量的燃烧室出口温度分布基本一致,两者测量的相对偏差在2%以内;同时表明燃气分析法在测量航空发动机燃烧室温度场具有测温上限高、测量准确的优点.

Abstract

In order to explore the applications of outlet temperature field measurement for a small annular combustor by gas analysis,the design of multipoint non-mixed water-cooled gas sampling probe was introduced for adaptation of a small annular combustor,two five-point non-mixed water-cooled gas sampling probes and double platinum rhodium thermocouple were fixed respectively on a displacement mechanism at the combustor outlet;swinging 180° with displacement mechanism,bidirectional data measurements were achieved;the gas temperature was calculated by measuring carbon dioxide(CO2),carbon monoxide(CO)and unburned hydrocarbons(UHC).Test results showed that the combustor outlet temperature fields measured by gas analysis method and thermocouple method were consistent basically,the relative deviation of them was within 2%;at the same time,gas analysis method was proven to be dominant in measuring high gas temperature from aeroengine combustor with high upper limit of temperature measurement and high precision.

关键词

出口温度场/小尺寸全环燃烧室/燃气分析/水冷燃气取样探针/位移机构/双向数据采集

Key words

outlet temperature field/small annular combustor/gas analysis/water-cooled gas sampling probe/displacement mechanism/bidirectional data measurement

引用本文复制引用

出版年

2024
航空动力学报
中国航空学会

航空动力学报

CSTPCD北大核心
影响因子:0.59