首页|低压电力电缆线路运行故障检修方法

低压电力电缆线路运行故障检修方法

扫码查看
传统方法检修时延性较差,且检修后线路电压仍然存在波动,线路故障检修效果不佳.提出低压电力电缆线路运行故障检修方法,利用行波检测仪采集电缆线路行波信号,采用小波阈值去噪法对信号滤波进行处理,根据行波信号与参考信号相似度,诊断线路是否存在故障;根据行波传播时间与传播速度,定位故障位置;通过故障树得到对应的故障维修方案,对线路进行维修.试验证明,设计方法延迟时间较短,检修后线路电压迅速恢复稳定状态,具有良好的故障检修效果.
Maintenance method of low-voltage power cable line operation fault
Due to the poor time delay of the traditional maintenance method,and the fluctuation of the line voltage after the maintenance,the effect of the line fault maintenance is not good,the maintenance method of low-voltage power cable line operation fault is proposed.Use the traveling wave detector to collect the traveling wave signal of the cable line,use the wavelet threshold denoising method to filter the signal,diagnose whether there is a fault in the line according to the similarity between the traveling wave signal and the reference model,locate the fault location according to the traveling wave propagation time and speed,use the fault tree to obtain the corresponding fault maintenance plan,and repair the line.The experiment proves that the design method has a short delay time,and the line voltage quickly recovers to a stable state after maintenance,which has a good fault maintenance effect.

low-voltage power cable linetroubleshootingtraveling wavewavelet threshold de-noising methodfault tree

张登峰

展开 >

中油电能电力技术服务公司,黑龙江 大庆 163000

低压电力电缆 故障检修 行波 小波阈值去噪法 故障树

2024

黑龙江电力
黑龙江省电机工程学会 黑龙江省电力科学研究院

黑龙江电力

影响因子:0.359
ISSN:1002-1663
年,卷(期):2024.46(4)
  • 6