首页|二次风箱改造后配风优化减缓高温腐蚀分析

二次风箱改造后配风优化减缓高温腐蚀分析

扫码查看
贵州某W火焰锅炉机组为满足超低排放进行了低氮燃烧改造,锅炉燃烧器至燃尽风区域经常处于局部缺氧燃烧状态,水冷壁高温腐蚀比较严重.为解决水冷壁局部缺氧燃烧及高温腐蚀问题,该厂进行了二次风箱分隔改造,同时进行了配风优化试验.二次风箱分隔改造后通过配风优化试验,保证了各分隔风箱风压基本一致,解决了燃烧器至燃尽风区域水冷壁局部缺氧燃烧问题,改善了水冷壁贴壁区域的还原性气氛,减缓了水冷壁高温腐蚀.
Analysis of Reducing High Temperature Corrosion by Air Distribution Optimization after Transformation of Secondary Bellows
In order to meet the ultra-low emission,a W-flame boiler unit in Guizhou has carried out low-nitrogen combustion transformation.The boiler burner to the over fire air area is often in a local anoxic combustion state,and the high-temperature corrosion of the water-wall is serious.In order to solve the problem of local anoxic combustion and high temperature corrosion of water wall,the plant has carried out the transformation of secondary bellows separation,and carried out the optimization test of air distribution.After the transformation of the secondary bellows,the air distribution optimization test ensured that the air pressure of each bellows was basically the same,solved the problem of local anoxic combustion of the water wall in the area from the burner to the over fire air,improved the reducing atmosphere in the area of the water wall,and slowed down the high temperature corrosion of the water wall.

W-flame boilersecondary bellows separation transformationair distribution optimization testslowed down the high temperature corrosion

喻国、陈玉忠、赵志军、袁军权、于洪明、王世远

展开 >

贵州创星电力科学研究院有限责任公司,贵州贵阳

W火焰锅炉 二次风箱分隔改造 配风优化试验 减缓高温腐蚀

2024

科学技术创新
黑龙江省科普事业中心

科学技术创新

影响因子:0.842
ISSN:1673-1328
年,卷(期):2024.(9)
  • 8