首页|下沉式道路排水系统设计研究

下沉式道路排水系统设计研究

扫码查看
本文主要探究了下沉式道路排水系统的设计要点.在设计中首先要根据径流系数、设计暴雨强度等参数,计算下沉路段的雨水设计流量.同时结合实地勘察判断下沉式路段的类型,对于两个或多个连续的下沉式路段,可以在相邻集水点之间布置连通管道,然后在最低集水点处修建泵房进行统一排水,有助于减小工程规模、控制工程成本.从下沉式道路排水系统设计的应用实例来看,该道路的雨水设计流量为1 308.6 m3/h,泵房设计流量为1.2倍的雨水设计流量,即1 570.3 m3/h.泵房内安装2台额定流量为800 m3/h的潜水泵,可以满足排水需要.
Design and Research on Sunken Road Drainage System
This article mainly explores the design points of sunken road drainage systems.In the design,the design flow of rainwater in the sinking section shall be calculated first according to the runoff coefficient,design rainstorm intensity and other parameters.At the same time,combining with on-site investigation to de-termine the type of sunken road section,for two or more continuous sunken road sections,connecting pipelines can be arranged between adjacent drainage points,and then a pump room can be built at the low-est drainage point for unified drainage,which helps to reduce the project scale and control project costs.From the application example of sunken road drainage system design,the rainwater design flow rate of the road is 1 308.6 m3/h,and the pump room design flow rate is 1.2 times the rainwater design flow rate,which is 1 570.3 m3/h.Install two submersible pumps with a rated flow rate of 800 m3/h in the pump room,which can meet the drainage needs.

sunken roadsrunoff coefficientdrainage systemrainstorm intensity

吕思思

展开 >

东阳市规划建筑设计院有限公司,浙江 东阳

下沉式道路 径流系数 排水系统 暴雨强度

2024

科学技术创新
黑龙江省科普事业中心

科学技术创新

影响因子:0.842
ISSN:1673-1328
年,卷(期):2024.(22)