换热管与管板的焊接是换热器质量控制的重点.双相不锈钢焊接的目标是获得平衡的铁素体(δ)和奥氏体(γ).采用手工钨极氩弧焊,使用Φ1.6 mm的ER2209焊丝,以0.54 kJ/mm的热输入焊接Φ25 mm×2 mm的S32205双相不锈钢换热管与管板试件.经取样检测,角焊缝厚度均值2.88 mm;焊缝维氏硬度均值255.8 HV;按ASTM E562测定铁素体含量,焊缝铁素体含量均值59.3%,管侧熔合线57.3%,管侧热影响区58%,板侧熔合线58.7%,板侧热影响区58.2%;按ASTM A923的方法A检测,5区的金相组织相界和晶界平滑,无有害沉淀相析出,评定为未受影响的金相组织;按GB/T 4334的方法E试验,无晶间腐蚀现象.以上各项检测指标均符合相应标准和技术协议要求,说明焊接工艺适用.
Welding Duplex Stainless Steel Heat Exchange Tube to Tubesheet
The welding of heat exchange tube and tubesheet is the key point of heat exchanger quality control.The goal of duplex stainless steel welding is to obtain the balance of ferrite(δ)and austenite(γ).The S32205 heat exchange tube and tubesheet specimens of Φ25 mm×2 mm were welded by manual TIG with Φ1.6 mm ER2209 and 0.54 kJ/mm heat input.After sampling and testing,the average thickness of fillet weld is 2.88 mm;average vickers hardness of weld 255.8 HV;According to ASTM E562,the average ferrite content of weld was 59.3%,tube side fusion line 57.3%,tube side HAZ 58%,plate side fusion line 58.7%,plate side HAZ 58.2%.According to ASTM A923 method A test,the phase boundary and grain boundary of the five zones were smooth,no harmful phase is precipitated,and assessed as unaffected metallographic structure.According to GB/T 4334 method E test,no intergranular corrosion phenomenon.The above test indicators are in line with the corresponding standards and technical agreement requirements,indicating that the welding process is applicable.