首页|氮掺杂碳点的制备及其在Hg2+测定中的应用研究

氮掺杂碳点的制备及其在Hg2+测定中的应用研究

扫码查看
以柠檬酸为碳源,尿素、邻菲罗啉、氨水、硫脲、精氨酸为氮源,通过水热法合成了5种氮掺杂荧光碳点.对合成的碳点进行荧光性能表征,测定了每种碳点的最佳激发和发射波长,在最佳发射波长下,利用荧光猝灭对Hg2+进行检测.结果表明,以精氨酸为氮源制备的碳点对Hg2+检测具有较灵敏的响应,其线性范围为0.25~1.5 µmol/L.
Preparation of N-doped carbon dots and application in Hg2+determination
Using citric acid as carbon source urea phenanthroline ammonia thiourea and arginine as nitrogen source,five kinds of nitrogen-doped fluorescent carbon dots were synthesized by hydrothermal method.The flu-orescence properties of the synthesized carbon dots were characterized,and the optimal excitation and emission wavelengths of each carbon dot were determined.Under the optimal emission wavelengths,Hg2+was detected by fluorescence quenching.The results show that the carbon dots prepared with arginine as nitrogen source have a sensitive response to Hg2+detection,and the linear range of Hg2+determination is 0.25~1.5 µmol/L.

nitrogen dopedcarbon dotshydrothermal methodHg2+

王肖文、吴文丽、杜文韬、钞瀚贤、陈建祥、丁明洁、李晓燕、李银峰

展开 >

河南城建学院材料与化工学院,河南平顶山 467036

氮掺杂 碳点 水热法 Hg2+

国家级大学生创新创业训练计划河南城建学院学术技术带头人项目

202211765019D2019007