ETT-X32气管插管联合纤维支气管镜吸痰加肺泡灌洗术在重症肺炎机械通气患者中的临床应用

扫码查看
目的:探究 ETT-X32 气管插管联合纤维支气管镜吸痰加肺泡灌洗术在重症肺炎机械通气患者中的应用和疗效.方法:选取 2010 年 4 月至 2023 年 5 月于某医院EICU住院需机械通气的重症肺炎患者 84 例,随机分为观察组和对照组各 42 例,观察组给予 ETT-X32 气管插管联合纤维支气管镜吸痰加肺泡灌洗术,按照气管插管护理常规护理患者.对照组应用普通有套囊性型气管插管未行纤维支气管镜治疗并按照气管插管护理常规护理患者.观察两组患者气囊压力、气囊对气管黏膜造成的压力性损伤;观察动脉血 PaCO2、PaO2、PaO2/FiO2 及炎症反应指标(PCT、TNF-α、IL-10).结果:观察组气囊压力有 89.2%的患者气囊压力能维持在正常范围,对照组仅有 48.96%的患者气囊压力能维持在正常范围,差异有统计学意义(P<0.05);观察组气管插管套囊对气管壁黏膜壁造成的压力性损伤发生率是 9.52%,对照组发生率是 76.19%,差异有统计学意义(P<0.05);治疗后两组 PCT、TNF-α、IL-10 水平均较治疗前降低,差异有统计学意义(P<0.05);治疗后两组动脉血PaCO2 较治疗前降低,PaO2、PaO2/FiO2 较治疗前增高,且观察组优于对照组,差异有统计学意义(P<0.05).观察组治疗效果总有效率 90.48%,对照组患者治疗效果总有效率 73.81%,差异有统计学意义(P<0.05).结论:ETT-X32 气管插管联合纤维支气管镜吸痰加肺泡灌洗术用于治疗重症肺炎机械通气患者疗效显著.
Clinical observation of ETT-X32 tracheal intubation combined with fiberoptic bronchoscopy sputum aspiration and alveolar lavage in patients with severe pneumonia undergoing mechanical ventilation
Objective:To explore the efficacy of ETT-X32 tracheal intubation combined with fiberoptic bronchoscopy sputum aspiration and alveolar lavage in patients with severe pneumonia undergoing mechanical ventilation.Methods:From April 2010 to May 2023,84 patients with severe pneumonia requiring mechanical ventilation in EICU of one hospital were selected,Randomly divided into observation and control groups.The clinical data of 42 patients who were given ETT-X32 tracheal intubation combined with fiberoptic bronchoscope sputum aspiration and alveolar lavage,and the patients were cared for according to the routine nursing of tracheal intubation were analyzed and included in the observation group.The 42 patients in the control group did not accept fiberoptic bronchoscopy after receiving conventional tracheal intubation,and the patients were managed according to the routine tracheal intubation care.Cuff pressure,tracheal mucosal damage,PaCO2,PaO2,PaO2/FiO2 in arterial blood and inflammatory reaction indexes(PCT,TNF-α,IL-10)were observed in both groups.Results:In the observation group,89.2%of the cuff pressure could be maintained in maintain the normal range,while only 48.96%of patients in the control group could maintain the normal range,the difference was statistically significant(P<0.05).In the observation group,the incidence of pressure injury to the tracheal wall mucosa caused by the tracheal intubation cuff was 9.52%,the incidence in the control group was 76.19%,and the difference was statistically significant(P<0.05).Before treatment,the levels of PCT,TNF-α,There were no significant difference in PaCO2、PaO2、PaO2/FiO2 were not significantly different(P>0.05).After treatment,the levels of PCT,TNF-αand IL-10 in both groups were lower than those before treatment.After treatment,PaCO2 in arterial blood of the two groups decreased compared with that before treatment.PaO2 and PaO2/FiO2 were higher than before treatment,and the observation group is better than the control group,the difference was statistically significant(P<0.05).The overall efficacy rate was 90.48%in the observation group and 73.81%in the control group,with statistical significance(P<0.05).Conclusion:ETT-X32 tracheal intubation combined with fiberoptic bronchoscopy sputum aspiration and alveolar lavage is effective in the treatment of severe pneumonia in mechanically ventilated patients.

ETT-X32 endotracheal intubationfiberoptic bronchoscopealveolar lavagecuff pressure monitoringsevere pneumonia

李倩倩、李晓钟、孔静、葛燕萍、许梦

展开 >

开封市人民医院 急诊医学科,河南 开封 475002

开封市医学科学研究所 急诊医学科,河南 开封 475000

ETT-X32气管插管 纤维支气管镜 肺泡灌洗 囊压监测 重症肺炎

河南省医学科技攻关计划联合共建

LHGJ20210837

2024

河南大学学报(医学版)
河南大学

河南大学学报(医学版)

影响因子:0.494
ISSN:1672-7606
年,卷(期):2024.43(1)
  • 12