首页|寒冷地区外窗热工性能对建筑采暖空调负荷的影响

寒冷地区外窗热工性能对建筑采暖空调负荷的影响

扫码查看
[目的]通过研究外窗热工性能对建筑采暖空调负荷的影响,得出各项外窗热工性能参数对建筑节能效果的影响程度,有助于提升建筑的节能效果.[方法]利用DeST-h,建立寒冷地区(郑州)75%节能标准居住建筑基本模型,以太阳得热系数、窗墙比、外窗传热系数为变量进行单因素影响计算,以窗墙比和太阳得热系数、建筑层数和太阳得热系数为变量进行多因素分析,研究太阳得热系数、窗墙比、外窗传热系数对建筑采暖空调负荷的影响.[结果]结果表明,窗墙比、传热系数对建筑采暖空调负荷影响趋势明显,均呈正相关;太阳得热系数对建筑采暖空调负荷影响趋势与建筑窗墙比、建筑层数有关.[结论]建筑外窗节能应优先考虑窗墙比、传热系数,同时在确定当地太阳得热系数时应兼顾窗墙比和建筑层数,以满足更高的节能标准.
Analysis of the Influence of Thermal Performance of External Window on Building Heating Air Conditioning Load in Cold Area
[Purposes]By studying the impact of external window thermal performance on building heat-ing air conditioning load,the degree of influence of various external window thermal performance param-eters on building energy efficiency is obtained,which helps to improve building energy efficiency.[Meth-ods]Using DeST-h,the basic model of 75%energy-saving standard residential building in cold area(Zhengzhou)was established,and the single factor influence calculation was carried out with solar heat gain coefficient,window-wall ratio and external window heat transfer coefficient as variables,and the ef-fects of solar heating coefficient,ratio of window to wall and heat transfer coefficient of exterior windows on building heating air conditioning loads were studied by using multi-factor analysis.[Findings]The results showed that the influence of window-wall ratio and heat transfer coefficient on building heating air conditioning loads was obvious and positive correlation.The influence trend of solar heating coeffi-cient on heating and air conditioning loads was related to the window-wall ratio and storey the number of buildings.[Conclusions]In order to meet the higher energy-saving standard,the window-wall ratio and heat transfer coefficient should be given priority to the energy-saving of exterior windows,and the window-wall ratio and the number of buildings should be taken into account when determining the local solar heating coefficient.

solar heat gain coefficientarea ratioof window to wallheat transfer coefficientbuilding heat-ing air conditioning load

李杰、潘玉勤、常建国

展开 >

河南省建筑科学研究院有限公司,河南 郑州 450053

太阳得热系数 窗墙比 传热系数 建筑采暖空调负荷

河南省重点研发专项项目

221111320200

2024

河南科技
河南省科学技术信息研究院

河南科技

影响因子:0.615
ISSN:1003-5168
年,卷(期):2024.51(11)