Renovation and Application of Top Insulator Room for Electric Dust Collection
In response to the problems of low dust collection efficiency,unstable power transmission,and high dust content at the outlet of Guixi Smelter's electric dust collection smelting,combined with production practice,the reasons that affect the efficiency of electric dust collection and unstable power transmission were studied.The top insulator chamber was renovated,and new materials were selected to change the previous support and sealing methods.Through transformation,the efficiency of electric dust collection has been improved,the indicators have been improved,the good results have been achieved,and the operation and maintenance costs have been saved.
electric dust collectioncopper content in waste acid solutiontop insulator chamber