首页|冶炼厂用水情况分析与节水减排措施探讨

冶炼厂用水情况分析与节水减排措施探讨

扫码查看
为了解某冶炼厂取用水不足之处,提出合理的节水减排措施,进行了全厂水平衡测试和生产废水水质分析.结果表明:(1)该厂生产污、废水量占生产新水量比值约为12%和14%;(2)该厂各类生产废水水质不适合直接回用,可采用膜前预处理+膜处理的末端减排方式减少废水排放量;(3)通过在循环水池新增空冷节水设备、整改地坑溢流排水、新增膜处理+膜前预处理工艺后,可节约生产新水约39.5%;(4)构建由水平衡示意图、分系统监控图、3D管网图、智慧水务管理报表、专家库系统组成的智慧水务系统,同时完善用水计量设施.提高该厂的水务管理水平.
Analysis of Water Use in Smelters and Discussion on Measures of Water Saving and Emission Reduction
In order to understand the shortcomings of water intake in a smelter,reasonable water-saving and emission reduction measures were proposed,and water balance tests and analysis of production wastewater quality were conducted for the entire plant.The results show that:(1)the proportion of production pollution and wastewater in the factory is about 12%and 14%.(2)The water quality of various production wastewater in the factory is not suitable for direct reuse.It is advisable to adopt a terminal emission reduction method of pre membrane pretreatment+membrane treatment to reduce the amount of wastewater discharged.(3)By adding air-cooled water-saving equipment in the circulating water tank,rectifying pit overflow drainage,and adding membrane treatment+pre membrane pretreatment processes,approximately 39.5%of new water production can be saved.(4)Build a smart water management system consisting of a water balance diagram,subsystem monitoring diagram,3D pipeline diagram,smart water management report,and expert database system,while improving water metering facilities.Improve the water management level of the factory.

water balanceproduction sewageproduction wastewaterwater saving and emission reduction

邓斌、胡苗福、陈晟、谢太李

展开 >

江西铜业集团(贵溪)冶金化工工程有限公司,江西贵溪 335424

江西铜业股份有限公司贵溪冶炼厂,江西贵溪 335424

水平衡 生产污水 生产废水 节水减排

2024

湖南有色金属
湖南有色金属研究院,湖南有色金属学会

湖南有色金属

影响因子:0.393
ISSN:1003-5540
年,卷(期):2024.40(2)
  • 6