首页|高效液相色谱法测定水中烷基酚类化合物和双酚A

高效液相色谱法测定水中烷基酚类化合物和双酚A

扫码查看
建立以固相萃取/高效液相色谱法测定水中 9 种烷基酚类化合物和双酚A的分析方法.方法采用固相萃取富集、净化处理水样,经安捷伦Eclispe XDB-C18 色谱柱分离后用荧光检测器检测.实验结果表明,9 种烷基酚类化合物和双酚A在 0~1000μg·L-1 范围内曲线线性关系较好,相关系数均在 0.999 以上,检出限为0.004~0.009μg·L-1.对0.25、1.00和2.50μg·L-1 3个浓度标准样品进行精密度和准确度测试,平行测定 7 次的精密度和准确度较好,相对误差范围为 0.2%~9.6%,相对标准偏差范围为 4.4%~11.9%,对实际样品进行 3 个不同浓度的加标回收率测试,加标回收率在79.8%~115%之间,样品加标回收率较好.
Determination of alkyl phenols and bisphenol A in water by HPLC
A method for determination of 9 alkyl phenols and bisphenol A in water by solid phase extraction/high performance liquid chromatography was established.The water samples were enriched and purified by solid phase extraction,separated by Agilent Eclispe XDB-C18 column and detected by fluorescence detector.The experimental results showed that the curves of 9 alkyl phenols and bisphenol A were linear in the range of 0~1000μg·L-1,the correlation coefficients were above 0.999,and the detection limits were 0.004~0.009μg·L-1.The precision and accuracy of the three concentration standard samples of 0.25μg·L-1,1.00μg·L-1 and 2.50μg·L-1 were tested.The precision and accuracy of the parallel determination for 7 times were better,the relative error range was 0.2%~9.6%,and the relative standard deviation range was 4.4%~11.9%.The recovery rate of three different concentrations of the actual sample was tested.The recovery rate of the sample was 79.8%~115%,and the recovery rate of the sample was good.

alkyl phenolsbisphenol Asolid phase extractionliquid chromatography

丁肖怡、柳鑫、韩增玉、韩文静

展开 >

宁夏回族自治区生态环境监测中心,宁夏 银川 750004

烷基酚类化合物 双酚A 固相萃取 液相色谱法

宁夏回族自治区重点研发计划

2019BFG02020

2024

化学工程师
黑龙江省化工研究院

化学工程师

CSTPCD
影响因子:0.243
ISSN:1002-1124
年,卷(期):2024.38(6)
  • 9