首页|气质联用法同时测定土壤中6种多溴联苯醚

气质联用法同时测定土壤中6种多溴联苯醚

扫码查看
建立了一种气质联用法同时测定土壤中6种多溴联苯醚化合物(PBDEs)的方法。采用10mL正己烷-丙酮(1∶1,V/V)溶剂提取,弗罗里硅固相萃取柱净化,10mL正已烷-二氯甲烷(1∶1,V/V)溶剂洗脱,氮吹浓缩至近干,用丙酮定容至1。0mL后进行GC-MS分析。实验结果表明,6种多溴联苯醚在5。00~400μg·L-1浓度范围内线性良好,方法检出限为1。5~3。4μg·kg1,加标回收率为89。0%~103。5%,标准偏差为2。0%~4。7%。本方法前处理操作简便,检出限低,精密度好,准确度高,适用于土壤中多种多溴联苯醚化合物的残留检测。
Simultaneous determination of six polybrominated diphenyl ethers in soil by GC-MS
A gas chromatography-mass spectrometry method was established for the simultaneous determination of six polybrominated diphenyl ether compounds(PBDEs)in soil.The extraction was carried out with 10mL n-hexane-acetone(1∶1,V/V)solvent,purified by Florisilicon solid phase extraction column,eluted with 10mL n-hexane-dichloromethane(1∶1,V/V)solvent,concentrated to near-dry by nitrogen blowing,and analyzed by GC-MS after constant volume of acetone to 1.0mL.The experimental results showed that the 6 kinds of PBDEs had good linearity in the concentration range of 5.00~400μg·L-1,the detection limit was 1.5~3.4μg·kg-1,the recoveries were 89.0%~103.5%,and the standard deviations were 2.0%~4.7%.The method has the advantages of simple operation,low detection limit,good precision and high accuracy,and is suitable for the residue detection of polybrominated diphenyl ethers in soil.

soilgas chromatography-mass spectrometrypolybrominated diphenyl ethers

张伟、朱丽丽

展开 >

山东省临沂生态环境监测中心,山东临沂 276000

潍坊市寿光生态环境监控中心,山东潍坊 262700

土壤 气相色谱-质谱联用 多溴联苯醚

2024

化学工程师
黑龙江省化工研究院

化学工程师

CSTPCD
影响因子:0.243
ISSN:1002-1124
年,卷(期):2024.38(12)